Installation
7.1

Electrical installation

A
NOTICE! Risk of damage
• Ensure cables are not damaged during installation.
• Ensure that a 12 V or 24 V stabilised power supply line is available for the
drive (rated power 13.2 W) at the point of installation.
• Ensure that the power supply line is suitably arranged and protected.
• Ensure that routings of cables through walls or bulkheads are protected
and insulated by appropriate bushing, grommets or cable conduits.
• Secure all cables to prevent any contact with moving parts.
Proceed as follows:
➤ Decide on the routing of the motor wire (fig. 2, page 3). Each head rail has
a separate cable (except for S1 or SO blind types).
➤ Check the voltage of the blind (see cable label).
➤ Choose a location for the control device (such as switch or remote control)
which must be installed in a visible location.
➤ Connect the blind according to the circuit diagram:
– Manually switched blinds (fig. 7, page 6)
– Remotely controlled blinds (fig. 8, page 6)
– Other control system (fig. 9, page 7)
Key to circuit diagrams:
Item
1
2
3
4
5
6
7
8
bk
rd
wh
gy
ye
22
Description
Fused 12 Vg or 24 Vg supply
(fuse rating: 3 A for 12 Vg, 2 A for 24 Vg)
Head rail motor
Second head rail motor (optional, only for DM versions)
Second head rail motor (optional, only for D2 and S2 versions)
Customer supplied switch (DPDT (double pole, double throw),
latching or momentary, 12/24 Vg, 3 A)
AP receiver
Automation system dry contact component (optional)
IRS-300
black
red
white
gray
yellow
Powered Roofblind