Tabla De Contenido; General Information; Packaging List; Appliance Data - Lennox Scandium-NG Instrucciones De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TABLE OF CONTENTS
Section
Contents
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
16.0
17.0
18.0
19.0
20.0
21.0
22.0
23.0
24.0
25.0
26.0
27.0
28.0
29.0

1.0 GENERAL INFORMATION

This appliance is a high efficiency, unvented, flame effect gas heater. It
provides radiant and convected warmth both efficiently and safely
utilizing the latest type catalytic convertor burner technology. The
appliance does not require a flue system of any type as the catalytic
converter cleans the flue products to provide a complete combustion
system, which is intrinsically safe.
These heaters are fitted with a specially designed pilot utilizing an
oxygen depletion sensor (ODS) which responds to the amount of
oxygen available in the room and shuts the heater off before the oxygen
level drops below 18%. The pilot can be relit only when fresh air is
available. Refer to the Combustion and Ventilation Air section.
The appliance is designed to fit various types of situations as listed in
the Installation Requirements.
This appliance is factory set for operation on the gas type, and at the
pressure stated on the appliance rating plate.
On first light up of a new appliance, initial curing of high temperature
paint and burning off of lubricants may occur for the first few hours of
operation. During this period some smoke may be emitted from outlet
grille, this should be no cause for concern. Accordingly, the room
should be well ventilated with all windows and doors open during this
period.
Read all these instructions before commencing installation. All
instructions must be handed to the user for safekeeping.

2.0 PACKAGING LIST

Page No.
QUANTITY
2
2
2
2
4
4
4
5
5

3.0 APPLIANCE DATA

6
6
Gas Type
7
Gas inlet pressure Maximum
7
7
7
Regulator Pressure Setting
8
Max Energy Input
8
Min Energy Input
9
Pilot Energy Input
9
Burner (Manifold) Pressure
9
10
Main burner flow restrictor
10
Oxypilot
10
Gas Inlet Connection
10
Ignition
11
Spark Gap
11
12
Please see Data Plate affixed to appliance for current data.
12
This appliance is for use only with the gas type, and at the pressure
13
stated on the appliance Data Plate.

4.0 IMPORTANT SAFETY INFORMATION

READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING OR OPERATING
YOUR UNVENTED ROOM HEATER.
T H E F O L L O W I N G B O X E D I N F O R M AT I O N A P P L I E S T O
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS.
Note: The following requirements reference various Massachusetts and
national codes not contained in this document.
Unvented Room Heaters shall be installed in accordance with 527 CMR
30.00 and 248 CMR 3.00 through 7.00:
(a) Permits and Inspections: In addition to complying with 248 CMR 3.05
the following requirements must be satisfied:
1. A permit shall be obtained from the head of the fire department and the
local or state gas inspector having jurisdiction for the installation of all
unvented propane or natural gas-fired space/room heaters.
2. The permits shall be conditioned upon final inspection and approval of
installation by the head of the fire department and the local or state gas
inspector having jurisdiction.
3. A copy of the manufacturer's installation/operating literature shall be
submitted with each permit application.
4. Before operation, the Head of the Fire Department and the local or state
gas inspector shall inspect the installation for compliance with 527 CMR
(Board of Fire Prevention Regulations) and 248 CMR (Board of State
Examiners of Plumbers and Gas Fitters).
2
1
Firebox and burner assembly
1
Installation and operating instructions
1
Glass facia panel assembly
1
Fitting template
1
Screw and wall plug pack
1
Rubber grommet
Natural Gas
10.5" w.c.
Minimum
6" w.c.
5" w.c.
11,950 BTU/hr
6,820 BTU/hr
560 BTU/hour
High
2.4" w.c.
Low
0.8" w.c.
2.0mm (0.079")
3/8" NPT at regulator
Piezo spark
1/8" - 3/16"
IMPORTANT

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido