CAUTION
During work, inspect whether milling rings
still freely rotate on axes. If it is not the case,
e.g. due to accumulated dust; it is necessary
to remove it from the milling head. For this
reason the machine should not be operated
without suction system connected!
8.1
Suction system
To ensure the operability of suction system, put
the hose (36 mm diameter) of some Festool brand
vacuum cleaner onto the handle adaptor [1-4].
Keep in mind that as fi ltration sack is being fi lled,
the suction effectiveness signifi cantly reduces.
Also clean vacuum cleaner's fi lter time to time.
CAUTION
Always operate the machine with the suction
system connected; otherwise, the milling rings
as well as suction fl ange height adjustment
system will be clogged with dust!
To prevent discharges of static electricity in dusty
environment, use vacuum cleaners of antistatic
models only.
8.2

Additional handle

To operate the grinder with both hands, it is pos-
sible to fasten an additional handle [1-1] to the
left-hand side of gearbox cover's front part.
The special "VIBRASTOP" design reduces vibra-
tions in the additional handle.
9
Service and maintenance
WARNING
Risk of accident, electric shock
 Always pull the plug out of the socket before
performing any type of work on the machine.
 All maintenance and repair work which re-
quires the motor housing to be opened, must
only be carried out by an authorised service
workshop.
- Wrapped electric tools can be stored in a dry
place without heating, with temperatures not
lower than –5°C. Unwrapped electric tools can
only be stored in dry places with temperatures
not lower than +5°C, without sudden changes
in the temperature.
16
- To ensure the airfl ow is suffi cient, cooling open-
ings of the motor must be always clean and free.
- The machine is equipped with special self-
disconnecting brushes. When the brushes are
worn, the power supply is automatically discon-
nected, and the machine is stopped.
- If the suction fl ange height adjustment system
does not operate smoothly, the fl ange must be
removed and cleaned.
Customer service and repair. Only
through manufacturer or service
workshops: Please find the nearest
address at: www.festool.net/service
Use only original Festool spare parts!
EKAT
4
Order No. at: www.festool.net/service
5
3
2
1
10 Environment
Do not throw the power tool in your household
waste! Dispose of the machine, accessories and
packaging at an environmentally-responsible recy-
cling centre! Observe the valid national regulations.
EU only: European Directive 2002/96/EC stipulate
that used electric power tools must be collected
separately and disposed of at an environmentally
responsible recycling centre.
Information on REACh:
www.festool.com/reach
11 EU Declaration of Conformity
Renovation Cutter
RG 80 E
Year of CE mark: 2013
We declare under sole responsibility that this
product comply with all relevant requirements
of the following directives, norms or normative
documents:
2006/42/EC, 2004/108/EC, 2011/65/EU, EN 55
014-1, EN 55 014-2, EN 60 745-1, EN 60 745-2-3,
EN 61 000-3-2, EN 61 000-3-3.
Festool Group GmbH & Co. KG
Wertstr. 20, D-73240 Wendlingen
Dr. Martin Zimmer
Head of Research, Development and Technical
Documentation
2013-04-15
Serial no.
769231, 768829,
768798

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

769231768829768798Renofix rg 80 e

Tabla de contenido