SPECIFICATIONS
Model
No-load speed (Low / High)
Wood (Thickness 18 mm)
Drilling
Metal (Thickness 1.6 mm)
Capacity
Machine screw
Driving
Wood screw
Rechargeable battery
Weight
Model
Charging voltage
Weight
NOTE
Due to HITACHI's continuing program of research and
development, the specifi cations herein are subject to
change without prior notice.
CHARGING
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to the receptacle.
When connecting the plug of the charger to a receptacle,
the pilot lamp will blink in red (At 1-second intervals).
Table 1
Before
charging
While
charging
Charging
Pilot lamp
complete
(red)
Overheat
standby
Charging
impossible
(2) Regarding the temperature of the rechargeable battery
The temperatures for rechargeable batteries are as
shown in the Table 2, and batteries that have become
hot should be cooled for a while before being recharged.
UC10SL2
10.8 V
0.35 kg
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
Lights for 1 second. Does not light
for 0.5 seconds. (off for 0.5 seconds)
Blinks
Lights for 0.1 seconds. Does not light for
Flickers
0.1 seconds. (off for 0.1 seconds)
DS10DAL
0 – 350 / 0 – 1300 min
29 mm
Steel: 10 mm
Aluminum: 12 mm
6 mm
5.8 mm (diameter) × 45 mm (length)
(Requires a pilot hole)
BCL1015S: Li-ion 10.8 V (1.3 Ah 3 cells)
BCL1015: Li-ion 10.8 V (1.5 Ah 3 cells)
BCL1030: Li-ion 10.8 V (3.0 Ah 6 cells)
1.0 kg (BCL1015S or BCL1015)
1.2 kg (BCL1030)
2. Insert the battery into the charger.
Firmly insert the battery into the charger till it contacts the
bottom of the charger as shown in Fig. 2.
3. Charging
When inserting a battery in the charger, the pilot lamp
will light up continuously in red.
When the battery becomes fully recharged, the
pilot lamp will blink in red (At 1-second intervals).
(See Table 1)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or the
rechargeable battery.
Battery overheated.
Unable to charge.
(Charging will commence
when battery cools)
Malfunction in the battery
or the charger
Table 2 Recharging ranges of batteries
Rechargeable batteries
BCL1015S, BCL1015, BCL1030
5
English
-1
Symbol mark
Temperatures at which the
battery can be recharged
0°C – 50°C