Machine Connection

Cables must have a male XLR connector on one
end and a female XLR connector on the other end
A word on termination: DMX is a resilient commu-
nication protocol, however errors still occasional-
ly occur. Termination reduces signal errors, and
therefore best practices include use of a ternina-
tor in all circumstances. If you are experiencing
problems with erratic fixture behavior, especially
over long signal cable runs, a terminator may help
improve performance.
To build your own DMX Terminator: Obtain a 120-
ohm, 1/4-watt resistor, and wire it between pins
2&3 of the last fixture. They are also readily availa-
ble from specialty retailers.
Complimentary signal cable can transmits sig-
nals to 20 unit fixtures at most. Signal amplifier
is a must to connect more fixtures

4. Troubleshooting

Problem
No response from fixture
when power is applies
P. 6
BEAMER 17R
ENGLISH VERSION
INPUT
1
2
3
Probable Cause(s)
No power to fixture
Primary fuse blown
Secondary fuse blown
OUTPUT
Common
1
DMX +
3
3
DMX -
1
120-ohm, 1/4-watt resistor
2
Remedy
Replace fuse
Replace fuse
Connect controller