Fixture resets but does not
respond correctly to con-
troller(DMX mode opera-
tion)
Colors cannot be mixed
Fixure does not reset cor-
rectly
No light, lamp cuts out
intermittently,or burns out
too quickly
Controller not connected
Incorrect addressing of the
fixtures
Bad data link connection
Conflict between tracking
and vector control
Data link not terminated
Defective fixture or 2 de-
vices transmitting on link
Random color mixing is on Turn o random color
Electronic or mechanical
failure
Lamp missing or blown
Fixture or lamp is too hot
Connect Controller
Check address setting on
fixture and controller
Inspect cables and cor-
rect poor connections
and/or broken cables.
Eliminate scene cross-
fade on controller
Insert termination plug
in output of last fixture
Bypass fixtures one at a
time until normal oper-
ation is regained:unplug
both connectors and
connect them directly
together
mixing
Contact service techni-
cian
Disconnect fixture and
replace lamp
Allow fixture to cool. If
problem persists,contact
service technician
P. 7
BEAMER 17R
ENGLISH VERSION