Maintenance Schedule
PERIOD
MAINTENANCE
Each 24 hours
Check the coolant level and replenish if
operation
necessary.
Visual check of
Report immediately, contact Ingersoll Rand
machine for any
authorized distributor for assistance if in
leaks, dust build up
doubt
or unusual noise or
vibration
When compressor
Drain air receiver of condensate, or check
is receiver mounted
that automatic drain is operating
Visual check
Blow clean if needed
condition of
package pre − lter
First 150 hours
Change the coolant lter.
Each month or 100
Remove and clean package pre
hours
replace if needed
Check the cooler(s) for build up of foreign
matter. Clean if necessary by blowing out
with air or by pressure washing.
CONDENSER
Every 4 months
Remove any dust from the condenser ns.
COMPRESSOR
Make sure compressor power consumption
complies with data plate speci cations.
ROUTINE MAINTENANCE
This section refers to the various components which require
periodic maintenance and replacement.
.
It should be noted that the intervals between service requirement
may be signi cantly reduced as a consequence of poor operating
environment. This would include ef fects of atmospheric contamination
and extremes of temperature.
The SERVICE/MAINTENANCE CHART indicates the various
components' descriptions and the intervals when maintenance has to
take place. Oil capacities, etc., can be found in the
INFORMATION section of this manual.
Compressed air can be dangerous if incorrectly handled. Before
doing any work on the unit, ensure that all pressure is vented from the
system and that the machine cannot be started accidentally.
CAUTION: Before beginning any work on the compressor, open,
lock and tag the main electrical disconnect and close the isolation
valve on the compressor discharge. Vent pressure from the unit
by slowly unscrewing the coolant ll cap one turn. Unscrewing
the ll cap opens a vent hole, drilled in the cap, allowing pressure
to release to atmosphere. Do not remove the ll cap until all
pressure has vented from the unit. Also vent piping by slightly
opening the drain valve. When opening the drain valve or the
coolant ll cap, stand clear of the valve discharge and wear
appropriate eye protection.
Ensure that maintenance personnel are properly trained,
competent and have read the Maintenance Manuals.
Prior to attempting any maintenance work, ensure that:
.
all air pressure is fully discharged and isolated from the system. If
the automatic blowdown valve is used for this purpose, then allow
enough time for it to complete the oper ation.
http://air.ingersollrand.com
PERIOD
Each year or
2000 hours
− lter,
Every two years or
8000 hours
Every 4 years or
16000 hours
18000 hours
.
the machine cannot be started accidentally or otherwise.
.
all residual electrical power sources (mains and battery) are
isolated.
Prior to opening or removing panels or covers to work
a machine, ensure that:
.
anyone entering the machine is aware of the reduced level of
protection and the additional hazards, including hot surfaces and
intermittently moving parts.
GENERAL
.
the machine cannot be started accidentally or otherwise.
Prior to attempting any maintenance work on a
machine, ensure that: −
DANGER
Only properly trained and competent persons should
undertake any maintenance tasks with the compressor running or
with electrical power connected.
.
the work carried out is limited to only those tasks which require the
machine to run.
.
the work carried out with safety protection devices disabled or
removed is limited to only those tasks which require the machine to be
running with safety protection devices disabled or removed.
.
all hazards present are known (e.g. pressurised components,
electrically live components, removed panels, covers and guards,
extreme temperatures, in ow and out ow of air, intermittently moving
parts, safety valve discharge etc.).
.
appropriate personal protective equipment is worn.
MAINTENANCE
MAINTENANCE
Check the operation of the high
temperature protection switch (109
Change the coolant lter.
Check scavenge ori ce for blockage, clean
if required.
Replace elements in IRGP and IRHE
lters.
Change the separator cartridge.
Check motors w/grease ttings - grease
bearings per motor data plate.
Change the Air Filter element.
Take coolant sample for uid analysis.
Change the package pre − lter.
CONDENSATE DRAINS
Completely disassemble the drains and
clean all their components.
Replace the Ultra Coolant at
whichever interval occurs rst.
Check and replace all items included within
2000 hour service
Replace sealed bearing without grease ttings
on motors.
Strip, clean and regrease or replace motor
bearings on motors with grease ttings.
Fit replacement electrical contactor tips.
33