Function as interface

Function of outputs

The output function is used together with an intelligent building instal-
lation (IBI) to get feedback from KLF 200. The output function gives the
user feedback as to whether an action has been executed, for instance
if the skylight has been closed. As feedback, the built-in output relay is
activated for 2 seconds.
Intelligent building installations
io-homecontrol
products can be combined with most intelligent building
®
installations (IBI). The IBI system must include an output module with
one or more programmable outputs. When the outputs from the IBI have
been connected to the input terminals on the interface, the relevant
io-homecontrol
products can be controlled via the interface. With two
®
outputs it is possible to control both function
io-homecontrol
product or a group of io-homecontrol
®
OUTPUT
INPUT
A B C D E
1
2 3 4
(A)
OUTPUT A connects to INPUT 1 and 2.
OUTPUT B connects to INPUT 3 and 4 etc.
22 VELUX
®
Max 30 V AC/DC
Max 50 mA
A B C D E
and function
in an
products.
®
INPUT
5 6 7 8 9 10
(B)
(C)
(D)
(E)
ENGLISH
Function as interface

Resetting

Change of configuration

Resetting
When resetting, all settings will be deleted and the interface reset to
factory settings.
10 sec
1
2 3 4
5 6 7 8 9 10
Press the RESET button on the back of the interface for ten seconds with
a pointed object until the red light-emitting diode is on. Subsequently, the
light-emitting diode turns yellow followed by a red flash.
When the light-emitting diode flashes yellow, the interface has been
reset. This may take up to 1 min.
Change of configuration
For more advanced settings via computer, tablet or smartphone, see sup-
plementary instruction
ENGLISH
enclosed with the product.