AUTO CHANGEOVER... AUTO MODE OPERATION
An automatic cooling and heating changeover operation system ensures easy control and year-round
air conditioning.
Once the desired temperature is set, unit operation is switched automatically between cooling
and heating according to the room temperature. In addition, fan control of the outdoor unit enables
cooling operation at outside temperature as low as -10 °C.
To select the AUTO mode:
1
Press the
2
Select the
Each time this button is pressed, the operation mode is changed in sequence:
(AUTO)
The set temperature is also displayed on the remote controller.
To stop operation:
Press the
After the operation mode is set once, the operation starts in the same mode as
the one set previously from the next time by simply pressing the
When the set temperature is to be changed:
T
O
O
W
A
R
M
• Press the
button to lower the temperature. One press lowers the temperature by about 1°C.
T
O
O
C
O
O
L
• Press the
button to raise the temperature. One press raises the temperature by about 1°C.
Description of "AUTO CHANGEOVER"
(1) Initial mode
1 When unit starts the operation with AUTO operation from off;
• If the room temperature is higher than the set temperature, operation starts in COOL mode.
• If the room temperature is equal to or lower than the set temperature, operation starts in HEAT mode.
(2) Mode change
1 COOL mode changes to HEAT mode when about 15 minutes have passed with the room temperature 2 degrees
below the set temperature.
2 HEAT mode changes to COOL mode when about 15 minutes have passed with the room temperature 2 degrees
above the set temperature.
NOTE:
If two or more indoor units are operating in multi system, there might be a case that the indoor unit, which is
operating in
(AUTO), cannot change over to the other operating mode (COOL
of standby. Refer to the detailed information for multi system air conditioner explained on the right.
6
O
N
O /
F F
button.
M
O
D
E
(AUTO) mode by pressing the
button.
(COOL)
(DRY)
(HEAT)
O
N
O /
F F
button.
HEAT) and becomes a state
Description of "AUTO RESTART FUNCTION"
• These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start
operation automatically in the same mode as the one set with the remote controller before the shutoff of the main
power.
• If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after
the main power is turned on.
• If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power
comes on, in the same mode as the one set with the remote controller before the emergency operation.
• If the unit is operated in "
in the memory. When the main power is turned on, the unit decides the operation mode by the initial room temperature
at restart and starts operation again.
Information for multi system air conditioner
Multi system air conditioner can connect two or more indoor units with one outdoor unit. According to the
capacity, two or more units can operate simultaneously.
• When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and the
other for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor units that will
start the operation later cannot operate, indicating an operation state. (Refer to the table of Operation Indicator lamp
O
N
O /
F F
button.
below.)
In this case, please set all the indoor units to the same operation mode.
• When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes (max.
10 minutes) to blow out the warm air.
• In the heating operation, the indoor unit that does not operate may get warm or the sound of refrigerant ß owing may be
heard. This is not a malfunction since the refrigerant continuously ß ows into the indoor unit that does not operate.
Details of display on the indoor unit
The operation indicator at the right side of the indoor unit indicates the operation state.
Operation Indicator
Operation indicator lamp
Indication
This shows that the air conditioner is operating to reach the
target temperature. Please wait until the target temperature is
obtained.
This shows that the room temperature is approaching the target
temperature.
This shows a state of standby for operation.
Please refer to Information for multi system air conditioner
above.
AUTO" mode before power failure, the operation mode (COOL, DRY or HEAT) is not stored
Lighted
Blinking
Not lighted
Operation state
Difference between target
temperature and room temperature
About 2°C or more
About 2°C or less