Gingival contouring: Aesthetic contouring

PerFect TCS II pays special dividends in tissue contouring for aesthetic
purposes. Frequently a minor procedure can greatly enhance the
patient's appearance. With care and practice, it is possible to
attain precise control of the amount of tissue removed to ensure
superior results, both aesthetically and therapeutically. In addition,
the smooth, pressureless cutting stroke reduces the time necessary
for most aesthetic contouring procedures. You may use either the
Straight Knife or the Long Loop electrode for aesthetic contouring.
Shave or "plane'' away tissue in successive thin layers until the
desired appearance is achieved.
Remember to allow 10–15 seconds for the tissue to cool before
cutting again in the same area.
In Figures 13 and 14, the operator has easily corrected a patient's
crooked smile resulting from a marked asymmetry of the gingival
levels of the incisors.

4. Technical Information

PerFect TCS II Electrosurge

Coltène/Whaledent Inc. Catalog Nos. S8230CE, S8230UK, S8240,
S8115 and S8100 (Additional suffixes are used to indicate differences
in types and quantity of included electrodes.)

General

Dimensions:
Weight (unit and attached footswitch): 2.4 kg (5.29 lbs.)
Safety Standards
EMC Standards
S8115 and S8100 Flat Blade USA style three prong AC plug
S8230CE Continental European style AC plug with earth contact
S8230UK British style three prong AC plug with fuse
S8240 Australian style three prong plug

Classification

Electrical: Class I, protective earth conductor utilized in power cord
Applied Part: Type BF
Equipment
not
suitable
FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN
OR NITROUS OXIDE.
<10s
Equipment Limitation
>30s
Intermittent operation maximum: 10s output energized, 30s
minimum de-energized. In other words, for continuous repetitive
use do not operate for more than 10 seconds followed by a
30 second resting period.

Electrical

Maximum Power Consumption 135 Watts
AC Line Voltage
S8100:
108 x 159 x 222 mm
(4 1/8 x 6 1/4 x 8 3/4")
IEC60601-1/1988, A1 and A2
IEC60601-2-2/2001
IEC60601-1-2
(NEMA 5-15P)
(IEC 60884-1 CEE7 VII)
(BS 1363)
(AS 3112:2000, NZS 198)
for
use
in
the
presence
100 VAC ± 10%, 50/60 Hz
S8115:
S8230CE, S8230UK:
S8240:
CUT Maximum Power Output
COAG Maximum Power Output
Output Impedance
Nominal Operating Frequency
Coag Modulation Frequency
Coag Modulation Waveshape

Transport and storage conditions

Temperature -40°C to +70°C (-40°F to 158°F)
Relative Humidity 10% to 100% including condensation
Atmospheric Pressure 500 hPa to 1060 hPa (7.25 psi to 15.4 psi)

Operational ambient conditions

Temperature
Relative Humidity
Atmospheric Pressure

5. Special Notes and Precautions

CAUTION:
Remove AC power by disconnecting line cord
before performing any maintenance on the unit.

Maintenance and service

PerFect TCS II has been carefully designed and constructed to
ensure reliability and long life. Other than protecting the unit from
misuse or damage, minimum maintenance is required. Should your
PerFect TCS II fail to perform in accordance with specifications, if
any component is dropped or mishandled, or if any evidence of
damage is found, the unit should not be used. Return it to your
dental dealer or to Coltène/Whaledent for servicing. We urge you
to periodically examine your unit and accessories for visible signs of
damage or wear. Yearly verification of performance characteristics
is recommended.
CAUTION:
Disconnect the PerFect TCS II from AC power
source before performing the following maintenance.

Sterilizing electrode sheaths

For safety and optimum performance, sterilize each electrode sheath
before initial use and after each subsequent use.
of
a
1.
Remove all debris from the electrode sheath by scrubbing with
brush and soap and water. Do not bend wire.
2.
Clean in an ultrasonic cleaner, (such as Coltène/Whaledent's
BioSonic
®
non-ammoniated
manufacturer's directions. Remove and rinse thoroughly.
3.
Sterilize electrode sheath via a gravity steam sterilizing cycle
at 132°C for 15 minutes in a bag according to the directions
of the sterilizer manufacturer. Do not use dry heat, cold
sterilization or chemiclave. Make sure connector area is dry
before assembly.
115 VAC ± 10%, 50/60 Hz
230 VAC ± 10%, 50/60 Hz
240 VAC ± 10%, 50/60 Hz
-10°C to +40°C
(14°F to 104°F)
30% to 75%
700 hPa to 1060 hPa
(10.2 to 15.4 psi)
Ultrasonic
Cleaner),
with
solution
diluted
in
7
55 Watts, ±10%
33 Watts, ±10%
600 Ohms
3.68 MHz
120 Hz
Square wave