Troubleshooting - Dometic CS-NC15 Instrucciones De Montaje

Ocultar thumbs Ver también para CS-NC15:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
CS-NC15, CS-NCVM
8.2
Start the cooling unit
➤ Switch in the cooling unit by turning the control button clockwise (fig. 1 2,
page 3).
If you turn the control button further, you can regulate the temperature.
8.3
Shutting down the cooling unit
If you do not intend to use the cooling device for a prolonged period, proceed as
follows:
➤ Turn the control to 0.
➤ Disconnect the power cable from the battery or pull the DC cable plug out of the
rectifier.
➤ Clean the cooling device.
➤ Leave the door slightly open over the cover.
This prevents odour build-up.
9

Troubleshooting

Compressor does not run
Fault
U
= 0 V
T
≤ U
U
T
ON
Start attempt with
≤ U
U
T
OFF
EN
Possible cause
The connection between the battery
and the electronics is interrupted
Main switch defective (if installed)
Additional supply line fuse has blown
(if installed)
Battery voltage is too low
Loose cables
Poor contact (corrosion)
Battery capacity too low
Cable cross section too low
Troubleshooting
Remedy
Establish a connection
Replace the main switch
Replace the fuse
Charge the battery
Establish a connection
Replace the battery
Replace the cable
(fig. 6, page 7)
17