EN
4. Specifications
MODEL
CAPACITY
VA/W
INPUT
Voltage
Voltage Range
OUTPUT
Voltage
Voltage Regulation(Batt.
Mode)
Frequency
Frequency Regulation (Batt.
Mode)
Output Waveform
BATTERY
Battery Type & Number
Back up Time (at a PC load
with 15" monitor)
Recharge Time
TRANSFER TIME
Typical
INDICATOR
AC Mode
Battery Mode
Low Battery at Battery Mode
Fault
Battery Weak at AC Mode
Battery Fault at AC Mode
AUDIBLE ALARM
Battery Mode
Low Battery at Battery Mode
Fault
Battery Weak at AC Mode
Battery Fault at AC Mode
PROTECTION
Full Protection
PHYSICAL
Dimension, DXWXH (mm)
Net Weight (kgs)
ENVIRONMENT
Operating Environment
Noise Level
PowerWalker
PowerWalker
VFD 400
VFD 600
400VA/200W
600VA/300W
110/120VAC or 220/230/240VAC
90‐145VAC / 170‐280VAC
110/120VAC or 220/230/240VAC
±10%
50Hz or 60Hz
+/‐1 Hz
Modified Sinewave
12V/4.5Ah x 1pc
12V/7Ah x 1pc
5 minutes
8 minutes
10 hours to 90% after complete discharge
2‐6ms
Green LED lighting
Green LED flashing every 4 seconds
Green LED flashing every second
Red LED lighting
Red LED flashing every 2 seconds for 30 seconds
Red LED flashing three times every 2 seconds
Sounding every 4 seconds
Sounding every second
Continuously sounding
Sounding every 2 seconds for 30 seconds
Sounding three times every 2 seconds
Discharge, overcharge, and overload protection
231x81x185
3.1
3.8
0‐ 40°C, 0‐90 % relative humidity (non‐condensing)
Less than 40dB
PowerWalker
VFD 1000
1000VA/600W
12V/7.2AH*2
30 minutes
312x94x250
6.7