4. Specifications 
 
 
MODEL 
 
CAPACITY  
VA/W 
INPUT 
Voltage 
 
Voltage Range 
OUTPUT 
Voltage 
Voltage Regulation(Batt. 
 
Mode) 
 
Frequency 
Frequency Regulation (Batt. 
 
Mode) 
 
Output Waveform 
BATTERY 
Battery Type & Number 
Back up Time (at a PC load 
 
with 15" monitor) 
 
Recharge Time 
TRANSFER TIME 
Typical 
INDICATOR 
AC Mode 
Battery Mode 
Low Battery at Battery Mode
Fault 
Battery Weak at AC Mode 
Battery Fault at AC Mode 
AUDIBLE ALARM 
Battery Mode 
Low Battery at Battery Mode
Fault 
Battery Weak at AC Mode 
Battery Fault at AC Mode 
PROTECTION 
Full Protection 
PHYSICAL 
Dimension, DXWXH (mm) 
Net Weight (kgs) 
ENVIRONMENT 
Operating Environment 
Noise Level 
 
PowerWalker 
PowerWalker 
VFD 400 
VFD 600 
400VA/200W 
600VA/300W 
110/120VAC or 220/230/240VAC 
90‐145VAC  /  170‐280VAC 
110/120VAC or 220/230/240VAC 
±10% 
50Hz or 60Hz 
+/‐1 Hz 
Modified Sinewave 
12V/4.5Ah x 1pc
12V/7Ah x 1pc 
5 minutes 
8 minutes 
10 hours to 90% after complete discharge 
2‐6ms 
Green LED lighting 
Green LED flashing every 4 seconds 
Green LED flashing every second 
Red LED lighting 
Red LED flashing every 2 seconds for 30 seconds 
Red LED flashing three times every 2 seconds 
Sounding every 4 seconds 
Sounding every second 
Continuously sounding 
Sounding every 2 seconds for 30 seconds 
Sounding three times every 2 seconds 
Discharge, overcharge, and overload protection 
231x81x185 
3.1 
3.8 
0‐ 40°C, 0‐90 % relative humidity (non‐condensing) 
Less than 40dB 
PowerWalker 
VFD 1000 
1000VA/600W 
12V/7.2AH*2 
30 minutes 
312x94x250 
6.7 

Publicidad