CHARACTERISTICS
Power supply: 12 V~ with the supplied transformer or 12 V
power supply (not provided)
Consumption:
50 mA in standby
Programming:
via the keypad front panel, memorised in the event of power
outage
Relay
(max. 1.5A, 12 V - 24 V): 1 relay: NO; NC; C terminals.
Time delay control: electric lock striker or lock, automatic opener, lighting...
On/Off Control: lighting...
Time delay:
relay with a duration of 1-99 seconds or On/Off function

SAFETY GUIDELINES

The transformer must always be mounted on the DIN track of a modular
board or projecting on a non-metal support using the two mounting holes. It
is understood that the terminal board covers must always be refitted and that
connection must be made to an electrical installation in compliance with the
NFC 15-100 standard for France ONLY ONCE THE WIRING HAS ALL BEEN
COMPLETED.
Protection: The transformer is equipped with a "PTC" thermal cut-out. In
the event of damage or a short-circuit, the following steps should be taken to
restore transformer protection
1. Disconnect the 230V power supply (for at least 2 min.)
2. Repair as required
3. Reconnect the 230V power supply
Default master code recording
press 56 + press
press a new default master
code (4 - 8 digits)
by default = 8 x the digit 1
+ press
New default master code
is saved
Instructions:
Enter your relay code and press
tional for the time-out you programmed.
If the relay is programmed in the On/Off mode, enter your relay code and
press
, to switch it off, re-enter your code and press #.
with a DC
Recording relay code
press 51 + press
press a new relay code
(4 - 8 digits)
by default = 12345678
+ press
New relay code
is saved
, the relay will be opera-

PROGRAMMING MODE

Start up the system
Connect the 12 V ~ or 12 V
Enter the default master code =
(8 x the digit 1) + press
The red LED lights up
Relay time-out
press 52 + press
press the relay time-out
(2 digits between 01 and 99)
e.g. : 05 = 5 seconds
00 = on/off
by default = 5 seconds
+ press
Time-out
is saved
RESET:
Press this key
(and hold down during the entire procedure).
Switch off the power supply immediately. Switch the power supply back on,
release
after 6 beeps.
= Melody
DEFAULT MODE
power supply
Enter the default relay code =
(12345678) + press
The door is open
(The green LED lights up)
or
The keyboard beeps 4 times = error
Reconfigure by default
press 50 + press
The system is reconfigured
by default
Relay code ≠ Master code