Install handle, see Fig. [7].
1. Grease the o-ring of the cap (Q) with special grease
supplied.
2. Attach handle (X1,Y1) or lever (Z1, Z2) and secure with
screw (X2, Y2).
3. Screw in cap (X3, Y3).
Adjusting thermostats
• Before putting into service
• Following all maintenance operations on the thermostatic
cartridge
- Open the shut-off valve via shut-off handle (D1) and check
the temperature of the water using a thermometer, see
Fig. [8].
- Turn regulating nut (E1) clockwise or counter-clockwise until
the water temperature has reached 100 °F.
- Attach scale ring (K) so that the 100 °F marking points
towards the front, screw on sleeve (L) and cap (M).
- Attach handle (Y1) or lever (Z2) and secure with screw (Y2).
- Screw in cap (Y3).
Temperature limitation
The safety stop limits the temperature range to 100 °F.
If a higher temperature is desired, turn the temperature handle
until a noticeable resistance is felt.
Prevention of frost damage
When the domestic water system is drained, thermostats must
be drained separately, since non-return valves are installed in
the hot and cold water connections.
The complete thermostat assemblies and non-return valves
must be removed.
Maintenance
Maintenance, see Figs. [9] to [12].
Inspect and clean all parts, replace if necessary and apply
special grease (order no. 18 012).
Shut-off hot and cold water supply, also possible by
closing the isolating valves, see fold-out page I, Figs. [2]
and [3].
1. Unscrew cap (Y3), see fold-out page II Fig. [9].
2. Remove screw (Y2) and detach handle (Y1).
3. Unscrew cap (M) and sleeve (L).
4. Remove scale ring (K).
5. Remove screws (J4) and escutcheon (J).
6. Remove escutcheon mounting base (J2).
7. By loosening bolts (E), the thermostat unit can be moved to
the right and to the left, see Fig. [2].
8. Close both isolating valves (F1) using an 8mm allen wrench.
English
I. Thermostatic cartridge, non-return valve and isolating
valves, see Fig. [9].
1. Same procedure as for closing isolating valves, steps 1 - 6.
2. Detach sleeve (H).
3. Remove clip (G1).
4. Detach stop ring (H1).
5. Loosen extension set (L1) using a 2.5mm allen wrench and
remove.
6. Remove thermostatic cartridge (M1) using a 24mm wrench.
7. Remove non-return valve (O1) using a 10mm allen wrench.
8. Remove isolating valve (F1) using an 8mm allen wrench.
Caution Shut-off main pipes beforehand..
Assemble in reverse order.
Observe correct installation position of stop ring (H1).
Readjustment is necessary after each maintenance operation
on the thermostatic cartridge (see Adjustment).
II. Headpart, see Fig. [10].
1. Unscrew cap (X3).
2. Remove screw (X2) and detach handle (X1).
3. Unscrew cap (Q).
4. Unscrew spindle (P).
5. Remove escutcheon (O).
6. Unscrew extension (P1).
7. Remove headpart (V1) using a 17mm socket wrench.
III.Handshower, see Fig. [11] and [12].
1. Remove spray disk (W1), see Fig. [11].
Guaranteed for 5 years, the "SpeedClean" jets can be freed of
limescale simply by wiping across them firmly with the palm of
your hand, see Fig. [12].
IV. Remove and clean flow regulator (13 934), see fold-out
page III.
Assemble in reverse order.
Replacement parts, see fold-out page III ( * = special
accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.