Blackout Mode
Blackout mode: when no DMX-signal is detected the unit goes in blackout waiting for a DMX-signal.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone.
Press the MENU button until "bLMd" is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select "Yes" (blackout on) or "No" (blackout off) mode.
Once the mode is selected, press the ENTER button to save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Manual Mode
Only used to test the colors of the panels, the selected color can NOT be permanently saved.
a. Press the MENU button until "Manu" is showing on the display.
b. Press the ENTER button, the display shows "red".
c. Use DOWN and UP buttons to select one of the 3 colors: red, green or blue.
d. Once the right color shows on the display, press the ENTER button to change it.
e. The display shows "0": use the DOWN and UP buttons to change the value between 0 and 255 and press
<ENTER> to confirm.
f. You can repeat the actions "c" to "e" to choose the other colors and change their values as well.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Adjust White balance
Makes it possible to adjust the white color when all colors are at maximum. For each of the 4
subpanels you can set different settings.
a. Press the MENU button until "bALA" is shown on the display.
b. Press the ENTER button to select: the display shows "red1".
c. Use the DOWN and UP buttons to choose the color you want to change. (for each panel you can change
the 3 colors. Examples: red1 = red on panel1 ~ blu3 =blue on panel3 ~ Gre4 = green on panel 4)
d. Press the ENTER button: all 4 subpanels turn to white color.
e. Use the DOWN and UP buttons to change the value for selected color from the selected subpanel and
confirm with <ENTER>.
f. Repeat the actions "c" to "e" until you are satisfied with the results or press the MENU button to return to
the other options in the setup menu.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Remark: You can only set values between 125 and 255.
Display on/off
Display on: display is always lit.
Display off: display is dark when not used.
Press the MENU button until the display shows "Led".
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select "On" (display always lit) or "Off" (display dark when not used).
Once the mode is selected, press the ENTER button to save it.
To go back to the main menu without any change press the MENU button shortly.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Display Inversion
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
Press the MENU button until "dISP" is shown on the display. (normal display)
Press the ENTER button to toggle between
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Auto Test
Used to activate the internal "self-test" program which checks all possibilities of the unit.
Press the MENU button until the display shows "teSt".
Press the ENTER button to start the internal self-test program.
To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
JB SYSTEMS
®
OPERATION MANUAL
(normal display) and
(display inversion).
5/65
LED QUADRO PANEL
ENGLISH
Fixture Hours
Used to show the number of working hours of the unit.
Press the MENU button until the display shows "FhrS".
Press the ENTER button to show the number of working hours in the display.
To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Software version
Used to show the software version that is installed in the unit
Press the MENU button until the display shows "ver".
Press the ENTER button to show the software version on the display.
To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
OVERHEAD INSTALLATION
Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during installation and
servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids.
Before installing make sure that the installation area can hold a minimum point load of 10times the
device's weight.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
HINTS FOR MECHANICAL INSTALLATION:
[A] You can install the units on a wall by fixing it with 4 square hooks. This is a simple
way but not suitable if you want to install the units permanently or if you want to fix the
panels to the ceiling. In those case better use the method below.
[B] This method can be used to fix the panels permanently to
wall and ceiling. If needed, you can easily remove a panel for
servicing.
1. While installing on a wall, best start with the bottom row.
2. First check the hole distances needed to fix
the panels.
3. Draw the 4 drill holes for 1 panel on the
installation surface.
4. Make sure to select adapted anchors,
screws, lock washers and plugs for the
weight and installation surface.
5. Drill the holes with adapted diameter.
6. Install the first panel with the display faced down. To install
the individual panels, do the following:
Remove the 6 screws that keep the semi-transparent
cover in place.
Remove the semi-transparent cover gently.
You will see 4 big holes: fix the panels gently through
these holes, using the fixing materials you selected in
point (4).
Put the semi-transparent cover gently back in place and
fix the 2 frames back using the 6 screws.
Very important: first make a plan of your installation and
how you will connect the cables. Make the correct settings in
JB SYSTEMS
®
OPERATION MANUAL
6/65
LED QUADRO PANEL