[TEST] will start up an automatic test mode, so you can check if all the projectors are
working.
o
[rESt] can be used to reset all the settings of the bar to the original factory settings
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the external optics at least once every 30 days.
 Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
Fuse:
Total Power consumption:
Sound Control:
DMX connections:
DMX channels:
PAR LED power:
PAR beam angle:
Derby LED power:
Laser Power:
Laser radiation class:
Flash LEDs:
Working temperature:
Laser Safety Standard:
Size:
Weight:
You can download the latest version of this user manual on our website: www.jb-systems.eu
JB SYSTEMS®
Use the [UP / DOWN] button to select the desired mode:
ON = function activated. When no new information needs to be shown on
the display, the display will turn off. As soon as new information is available
(for example: when you use the remote control to select another mode) the
display will turn on automatically to show you this new information. After a
while, it will turn off again.
OFF = function deactivated. The LED display will be always lit.
Press the [ENTER] button to confirm your setting
Just press the [ENTER] button to reset the bar.
AC 100~240V, 50/60Hz
250V 2A slow blow (20mm glass)
48W
Internal microphone
3pin XLR male / female
3, 5, 6, 9 or 27 channels
2 projectors with each 3x 9Watt Tri LEDs
15°
2 projectors with each a 3W Red, 3W Green and 3W Blue LED
30mW 532nm Green, 100mW 650nm Red
3R
4x 1W white LED
10°C to 40°C
EN/IEC 60825-1 2007
1185x386x110mm
Bar= 6.6kg , Bar + Flight-case = 8.35kg