5. SETUP

5.1 Installation
Install the device on a plane surface or install it in rack.
Rack-installation: This device is built for 19" racks (483 mm). The rack you use should be a Double-Door-
Rack where you can open the frontpanel and the rear panel. The rack should be provided with a cooling fan.
When mounting the controller into the rack, please make sure that there is enough space around the device
so that the heated air can be passed on. Steady overheating will damage your device.
You can fix the controller with four screws M6 in the rack.

5.2 Analog input

Connect your light controller with the Analog Input socket.
The occupation of the 8-pin DIN-socket is as follows:
1. Channel 1
2. Channel 2
3. Channel 3
5.3 Outputs
Output of the DPX-610 via the terminal blocks is located beneath the blind plate on the rear panel.
Output of the DPX-610 MP via the 16-pin industrial sockets is located on the rear panel.
Output of the DPX-610 S via the safety sockets is located on the rear panel.
Connect your loads via the connectors. The maximum load per channel is 2300 W. Please note that the
maximum current of 60 A must never be exceeded.
The occupation of the 16-pin industrial socket is:
Output of the DPX-620 via the terminal blocks is located beneath the blind plate on the rear panel.
Connect your loads via the pole connectors. The maximum load per channel is 4600 W. Please note that the
maximum current of 120 A must never be exceeded.

5.4 DMX-512 control

The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the device or one device with another.
4. Channel 4
5. Channel 5
6. Channel 6
the devices will not work at all, or will not work properly.
7. Ground
8. Not connected