7. CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
If the fuse interrupts, please reset the breaker.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device will be damaged, it has to be replaced by authorized dealers only in
order to avoid hazards.
If defective, please dispose of the unusable device in accordance with the current legal regulations.
Should you have further questions, please contact your dealer.
8. TECHNICAL SPECIFICATIONS
DPX-610 + RCD
Power supply:
230-380 V AC,
50 Hz ~
Max. power output:
13800 W
Max. current:
60 A
Number of control-
6
channels:
Max. output/channel: 2300 W
Max.
10 A
current/channel:
Integrated programs: 12
Output sockets:
Via pole connectors Safety socket
Circuit breaker:
6 x C 10 A
Dimensions
410 x 482 x 95 mm
(WxDxH):
19" mounting
dimensions with 2 u
Minimum mounting
500 mm
depth:
Weight:
8 kg
Please note: Every information is subject to change without prior notice. 05.03.2009 ©
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
DPX-610 S
230-380 V AC,
50 Hz ~
13800 W
60 A
6
2300 W
10 A
12
6 x C 10 A
410 x 482 x 95 mm
19" mounting
dimensions with 2 u
500 mm
8 kg
DPX-610 MP
230-380 V AC,
50 Hz ~
13800 W
60 A
6
2300 W
10 A
12
16-pin industrial
6 x C 10 A
443 x 482 x 95 mm
19" mounting
dimensions with 2 u
500 mm
8,5 kg
24/39
DPX-620
230-380 V AC,
50 Hz ~
27600 W
120 A
6
4600 W
20 A
12
Via pole connectors
6 x C 20 A
420x 482 x 95 mm
19" mounting
dimensions with 2 u
500 mm
8 kg
00026417.DOC, Version 3.1