ASSEMBLY INSTRUCTIONS
System and installation must comply with state and local regulations.
Prior to assembly, compare the main diagram with your PiMag Waterfall
Water System, and make sure all the components are present.
1. Wash the inside of the water fill tank (E), the supply tank cover (F) and the inside of
the water supply tank (G) with water and a mild detergent or soap.
IMPORTANT: Do not use a scrubber sponge or dry with paper towels. Rinse both
tanks very thoroughly. Do not wet the battery compartment when washing.
• Place the supply tank on the base (H).
• Remove mineral stones from package, rinse thoroughly and
place inside the supply tank.
IMPORTANT: Do not put mineral stones in the circular recess located
in the center of the supply tank. This space is required for inserting
the filter column.
The water tap (I) is provided fully assembled and attached to the
tank. If disassembly is necessary, remove and reattach as follows:
• The water tap is supplied with two ring seals — one is placed on each
side of the supply tank wall. To remove, unscrew the magnetic tube (L)
from the tap and detach the magnetic tube ring seal (K).
• The tap assembly is connected to the filter life indicator by a wire. To disconnect this wire the
front plate must be removed. See the illustration and instructions in the REPLACING
BATTERY section for directions on how to remove the front plate.
• To reassemble, push the tap ring seal (J) all the way up against the end of the tap.
• Insert the tap through the hole in the supply tank. Attach the electrical wire connection and
replace the front plate.
• Push the magnetic tube ring seal (K) onto the end of the tap pipe, inside the supply tank.
• Screw on the magnetic tube and tighten until both ring seals are snug against both sides of
the tank.
2. Place the supply tank cover (F) on the water supply tank (G).
• Place water fill tank (E) on top of this cover.
3. Remove packaging from filter assembly (B, C, D). Pull off the top cap (B) of filter
assembly and set aside. Remove all prefilter pads (C).
4. Place the filter cartridge upright in an empty pot or pail, with the top of the
cartridge upward. Slowly fill the pail with cold water.
IMPORTANT: Do not use hot water. Do not use soap or detergent
to clean the cartridge.
• Continue filling until the level of the water is just below the
top of the cartridge. Do not overfill. Do not allow the water
level to cover the top of the filter cartridge.
• Place the five prefilter pads inside the pail. Allow all the
pads and the cylinder to soak at least 8 hours. If the level of
water in the pail drops, refill as necessary. For best results,
exercise care to avoid submerging the top of the filter cartridge.
5. After soaking is complete, reassemble the filter cartridge, prefilter pads and top
cap. Install the assembled filter in the Waterfall unit.
6. Remove the cover (A) from the top of the Waterfall tank and fill the unit with cold
water. Pull outward on the water tap lever to lift until it locks in the open position,
for draining.
• Fill and drain the unit while the tap is open, for two full cycles.
5