Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

THERMO-HYGROMETER
TERMO-HIGRÓMETRO
E N G L I S H
Quality AEMC Products Online at:
E S PA Ñ O L
GlobalTestSupply
User Manual
www.
Manual de Instrucciones
CA846
.com
sales@GlobalTestSupply.com

Publicidad

Capítulos

Tabla de contenido
loading

Resumen de contenidos para AEMC CA846

  • Página 1 CA846 THERMO-HYGROMETER  TERMO-HIGRÓMETRO  GlobalTestSupply E N G L I S H User Manual www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com E S PA Ñ O L Manual de Instrucciones...
  • Página 2: Statement Of Compliance

    The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: ________________________________ Catalog #: 2121.24 Model #:...
  • Página 3: Tabla De Contenido

    4.1 Recommendations ..............8 4.2 Operating the Model CA846 .............8 5. MAINTENANCE ................9 5.1 Replacing the Battery ...............9 5.2 Cleaning ..................9 Repair and Calibration ................10 Technical and Sales Assistance ............10 Limited Warranty ................... 11 Warranty Repairs ................... 11 GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Thermo-Hygrometer Model CA846...
  • Página 4: Introduction

    This symbol refers to a type A current sensor. This symbol signifies that application around and removal from HAZARDOUS LIVE conductors is permitted. In conformity with WEEE 2002/96/EC GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Thermo-Hygrometer Model CA846...
  • Página 5: Definition Of Measurement Categories

    Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. Ordering Information Thermo-Hygrometer Model CA846 ........Cat. #2121.24 Includes meter, shockproof holster, 9V battery and user manual. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com...
  • Página 6: Product Features

    CHAPTER 2 PRODUCT FEATURES Description The Thermo-Hygrometer Model CA846 is a portable, compact digital meter designed for simplicity and one-hand operation. The meter uses an NTC as the temperature sensor providing excellent response time to changes in temperature, good repeatability and accurate readings. The Model CA846 also utilizes a thin-film polymer-capacitive type relative humidity sensor as hygrometer sensor, offering excellent recovery from 100% moisture and fast response time and durability. 1. Temperature/humidity sensor with protective sensor cover 2. 3½ digit display 3. MAX button 4. °C/°F selector & backlight 5. HOLD button 6. Power/mode selector GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Thermo-Hygrometer Model CA846...
  • Página 7: Push Buttons

    • Press the button for 2 seconds to change the temperature scale to °C or °F. The temperature scale °C or °F is displayed in the lower right hand corner of the display. 2.2.3 MAX Button • Press the MAX button to enter the MAX mode. The “MAX” annunciator appears in the upper right hand corner of the display. • The selected range (%RH or °C/°F) records and updates the maximum absolute values. • Press the MAX button again to exit the MAX-recording mode (“MAX” goes out). • The HOLD button may be used in the MAX mode to “Freeze” (no longer updates) the MAX measurement on the display. 2.2.4 HOLD Button The Hold button “freezes” the reading on the display. Press the “HOLD” button to toggle (activate/release) HOLD. In the HOLD mode, the “HOLD” annunciator is displayed in the upper part of the LCD display and the last reading is displayed until released. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Thermo-Hygrometer Model CA846...
  • Página 8: Specifications

    Sensor Stability: ±2% RH, 2 years typical Sensor Hysterisis (10% to 90% to 10% RH): ±1% RH typical Sensor Temperature Dependence: Negligible from 32° to 140°F (0° to 60°C) Operating Temperature: 32° to 122°F (0°C to 50°C) at < 80% RH Storage Temperature: -4° to 140°F (-20° to 60°C), 0 to 80% RH with battery removed GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Thermo-Hygrometer Model CA846...
  • Página 9: Mechanical Specifications

    200 hours typical with carbon zinc battery Dimensions: 6.81 x 2.38 x 1.5" (173 x 60.5 x 38mm) Weight: Approx 7 oz (197g) including battery Safety Specifications EN 61010-1 (1995-A2), Protection Class III Overvoltage Category (CAT III, 24V), Pollution Degree 2 Indoor Use *All specifications are subject to change without notice GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Thermo-Hygrometer Model CA846...
  • Página 10: Operation

    • Avoid temperature measurement errors induced by too short mea- surement time, sunshine during the measurement, heating, cold outer walls, air draft (e.g. fans), radiating sources including hand and/or body heat, etc. • Avoid humidity measurement errors induced by steam, water splashes, dripping water or condensation on the sensor, etc. • Avoid sensor contamination induced by particles in the air or measure- ments in powder like substances. Contamination may be avoided by measuring through a filter (user supplied). The filter must be cleaned or replaced periodically, depending upon the degree of contamination at the measurement site. Operating the Model CA846 1. Unscrew the protective metal tube covering the sensor. 2. Set the power switch to the desired %RH or °C/°F range. 3. Let the reading(s) stabilize (%RH takes at least 60 seconds to reach 90%). 4. Read the display. 5. After use, screw the protective metal tube back onto the sensor. 6. Turn the instrument OFF when finished. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com...
  • Página 11: Maintenance

    CHAPTER 5 MAINTENANCE Use only factory specified replacement parts. AEMC will not be held ® responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. Replacing the Battery symbol appears on the LCD display when replacement is needed. Replace with a standard 9V battery (NEDA 1604, IEC 6F22). To replace the battery: • Turn the Thermo-Hygrometer OFF. • Remove the rubber holster. • Remove the screw from the back of the meter and lift off the battery cover. • Replace the battery, then put the rear cover and holster back on.
  • Página 12: Repair And Calibration

    Chauvin Arnoux , Inc. ® d.b.a. AEMC Instruments 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 techsupport@aemc.com www.aemc.com GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com NOTE: Do not ship Instruments to our Foxborough, MA address. Thermo-Hygrometer Model CA846...
  • Página 13: Limited Warranty

    For full and detailed warranty coverage, please read the Warranty Cov- erage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the War- ranty Coverage Information with your records. What AEMC Instruments will do: ®...
  • Página 14 NOTES: GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Thermo-Hygrometer Model CA846...
  • Página 15: Español

    4.1 Recomendaciones ..............20 4.2 Operación ................20 5. MANTENIMIENTO ................. 21 5.1 Reemplazo de la Batería ............21 5.2 Limpieza .................21 Reparación y Calibración ..............22 Asistencia Técnica y de Ventas .............22 Garantía Limitada ..................23 Reparaciones bajo Garantía..............23 GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 16: Introducción

    ¡Peligro! Riesgo de shock eléctrico. La tensión en la parte marcada con este símbolo puede ser peligroso De conformidad con WEEE 2002/96/EC GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 17: Definición De Las Categorías De Medición

    Si el equipo aparece dañado, presente un reclamo inmediatamente al transportador y avise inmediatamente a su distribuidor, dando una des- cripción detallada de los daños. Conserve el empaque dañado para res- paldar su reclamo. No utilice un instrumento que aparezca dañado. Información para poner una Orden Termo-Higrómetro Modelo CA846 ........Cat. #2121.24 Incluye una batería Alcalina de 9V, un protector gris rugoso a pruebas de golpes y resistente al polvo y manual del usuario GlobalTestSupply www.
  • Página 18: Características Del Producto

    CAPÍTULO 2 CARACTERÍSTICAS DEL PRODUCTO Descripción El Modelo CA846 de AEMC es un Termo-Higrómetro digital portátil, com- ® pacto y fácil de usar diseñado para operarlo con una sola mano. Utiliza un sensor NTC y un sensor de humedad capacitivo formado por una película delgada de polímero. El Termo-Higrómetro se entrega con el sensor y una funda protectora de goma. El Modelo CA846 posee también una pantalla de LCD con ilumi- nación posterior, una función mantener lectura (HOLD), y una función de registro de máximos (MAX). 1. SensorTemperatura/Humedad y cubierta protectora del sensor 2. Pantalla de 3½ digitos 3. Botón MAX (Máximo) 4. Selector °C/°F y Luz Posterior 5. Botón HOLD (Guardar) 6. Selector Encendido/Modo (Temp.-RH) GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com...
  • Página 19: Botones

    • El botón HOLD (vea abajo) puede ser usado en el modo MAX para “congelar” (no se actualiza más) la lectura MAX en la pantalla. 2.2.4 Botón HOLD El botón HOLD “congela” la lectura en la pantalla. Presione el botón “HOLD” alternadamente para activar/desactivar la función HOLD. En el modo HOLD, el símbolo “HOLD” aparece en la parte superior de la panta- lla LCD y se muestra la última lectura hasta que se desactive este modo. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 20: Especificaciones

    Tiempo de Respuesta del Sensor para 90% del Rango: Valor típico 60s Estabilidad del Sensor: ±2%HR, valor típico 2 años Histéresis del Sensor (10% a 90% a 10% HR): valor típico ±1%HR Dependencia de la temperatura del Sensor: Despreciable de 32° a 140°F (0° a 60°C) GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 21: Especificaciones De Mecanicas

    Velocidad de Muestreo: nominal, 2.5 veces por segundo. Batería: Batería Estándar de 9V (NEDA 1604, IEC 6F22 006P, o equiva- lente) Duración de la Batería: Valor típico 200 horas con batería de cinc-car- bón Dimensiones: 6.81 x 2.38 x 1.5 (173 x 60.5 x 38mm) Peso: Aprox 7 oz (197g) incluyendo batería Especificaciones de Seguridad EN 61010-1 (1995-A2), Protección Clase III Categoría de Sobrevoltaje (CAT III, 24V), Contaminación Grado 2 Uso Interior GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 22: Operación

    El filtro debe ser limpiado o reemplazado periódica- mente, dependiendo del grado de contaminación en el sitio de medi- ción. Operación 1. Remueva el tubo metálico protector que cubre el sensor, destornillán- dolo. 2. Coloque el interruptor de encendido en el rango deseado %HR o ºC/ ºF. 3. Deje que la(s) lectura(s) se estabilice(n). El %HR toma al menos 60 segundos en alcanzar 90%. 4. Lea la pantalla. 5. Después de usarlo, reponga el tubo metálico protector que cubre el sensor, atornillándolo. GlobalTestSupply 6. Apague el instrumento cuando haya terminado www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 23: Mantenimiento

    • Remueva la funda de goma. • Remueva el tornillo en la parte posterior del medidor y levante la cubierta de la batería. • Reemplace la batería y reponga la cubierta y la funda. Limpieza • Periódicamente limpie la caja con un paño húmedo y un detergente suave, si se requiere. • No utilice abrasivos ni solventes. • No permita que entre líquido a la caja o a la zona del sensor. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 24: Reparación Y Calibración

    , Inc. ® d.b.a. AEMC Instruments ® 200 Foxborough Boulevard Foxborough, MA 02035, USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 techsupport@aemc.com www.aemc.com NOTA: No envíe instrumentos a nuestra dirección en Foxborough, MA. GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 25: Garantía Limitada

    Garantía Limitada garantizados al propietario por El Termo-Higrómetro Modelo CA846 es defectos de fabricación, por un período de un año desde la fecha original de compra. Esta garantía limitada es dada por AEMC Instruments, no ® por el distribuidor a quien se compró el instrumento. Esta garantía queda viciada si la unidad ha sido intervenida, abusada o si la falla se relaciona con un servicio no realizado por AEMC Instruments. ® Para detalles y una descripción completa de la cobertura de la garantía, por favor lea la Tarjeta de Cobertura de Garantía, que se adjunta a la Tar-...
  • Página 26 NOTAS: GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com Termo-Higrómetro Modelo CA846...
  • Página 27 GlobalTestSupply www. .com Quality AEMC Products Online at: sales@GlobalTestSupply.com...
  • Página 28 07/08 99-MAN 100240 v5 GlobalTestSupply Chauvin Arnoux , Inc. d.b.a. AEMC Instruments www. .com Quality AEMC Products Online at: ® ® sales@GlobalTestSupply.com 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

Tabla de contenido