Troubleshooting
The jaw will not fit properly onto the press
Check that the pressing rollers are fully retracted. If not, press on the trigger until the rollers are fully retracted into the
body of the setting press.
The setting press will not start
Diagnosis:
The brushes are worn
The battery is flat
The motor is faulty
Trigger pressed too briefly
The rollers are not retracted
The machine has exceeded 18,000 cycles
The jaw will not fully close
Diagnosis:
The motor is faulty
The battery is flat
The main jaw is defective
The brushes are worn
The inserts used are not suitable for the fitting
The fittings exceed the maximum capacity of the machine
Inspection and maintenance of inserts and jaws
Insert guaranteed 5 years (except profile).
Before using, read these instructions as well as the machine operating instructions and the coupling manufacturer's
instructions. Failure to fully follow and understand these instructions may result in serious material damage and serious or
even fatal injury.
Safety:
● Wear eye protection when working, to protect against projectiles.
● Only use Virax inserts.
● Failure to use the machine in accordance with our instructions may result in serious or even fatal injury.
● Keep hands and fingers away from the pliers during the pressing cycle to avoid any risk of crushing or amputation.
● Never replace components yourself. Any component that has been modified in any way whatsoever may cause serious
or fatal injury.
Servicing and maintenance:
- Check daily that the profile of your inserts is as shown in the photographs page 3 :
Profile H-ML: 1, Profile G: 2, Profile TH: 3, Profile V: 4, Profile U: 5, Profile HA: 6, Profile RF-P: 7, Profile VUS: 8
- Check for corrosion, dirt or accumulated foreign matter daily.
- Clean the inserts with a medium or coarse steel wool then lightly oil the pressing profiles daily. Avoid using abrasive
materials such as emery board, sandpaper, abrasive materials, a grinding file or a rotary file, as this might damage the
inserts or alter their dimensions. Any modifications risk to cause leaks.
- Regularly check the condition of the main jaw. Check that the jaws close correctly (with the inserts in place!).
- If the formation of whiskers prevents the inserts coming into contact at the end of the pressing operation, replace the
inserts.
- Return the inserts to your dealer for inspection once a year.
- Clean and lubricate the hinge pins of the main jaw with bearing grease annually without removing.
- Clean, lubricate and check the working of the spring daily (the pliers must open without effort and close on their own).
- Visually inspect the jaw components every day.
If abnormal wear or cracks can be seen on one of the jaw components, it must be replaced.
Never replace components yourself. Any component that has been modified in any way whatsoever may cause
serious or fatal injury.
Using a damaged jaw or inserts will cause serious material damage and/or injury.
14
Remedy:
Send tool for repair
Recharge the battery
Send tool for repair
Hold down the trigger for longer
Press the trigger
Send the machine for servicing
Remedy:
Send tool for repair
Recharge the battery
Change the main jaw
Send tool for repair
Select the inserts recommended by the fitting manufacturer
See "Technical characteristics"