ROTHOBLAAS TOWER Manual De Uso página 25

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
INSTALLATION ON TIMBER STRUCTURE
Minimum beam size: 160x160 mm –min. quality GL24h
(as per EN14080)
Indispensable premise is a statically stable substructure.
If in doubt, consult a calculation expert.
Screws required for fastening the device to the structure:
1 set BEF201VGS containing 8 wood screws type VGS Ø 9 mm,
160 mm long and 4 washers
This set is available at: Rotho Blaas srl –Via Dell' A dige 2/1 – 39040
Cortaccia (BZ) - www.rothoblaas.com
The minimum penetration depth of the fastening screws
into the wood bearing structure must be equal to 145 mm.
Always position Rothoblaas TOWER - TOWER22 - TOWERA2 at the
center of the beam.
Fasten using 1 BEF201VGS fastening set, making sure to use the wa-
shers together with the screws for corner holes.
Install the screws as shown in the illustration above.
Alternative fastening devices:
• TOWERSLOPE (for TOWER22)
• TOWERPEAK (for TOWER 300/400/500/600)
WARNING: Follow the corresponding assembly procedure closely!
INSTALLATION ON CONCRETE STRUCTURE
Min. quality: C 20/25
Indispensable premise is a statically stable substructure. If in doubt,
consult a calculation expert.
HEAVY METAL ANCHOR:
For cracked and uncracked concrete
4 pieces FE210440 (12 x 103 mm) or longer
These heavy metal anchors are available at:
Rotho Blaas srl - Via dell' A dige 2/1 - 39040 Cortaccia (BZ) -
www.rothoblaas.com
Indications as per manufacturer's worksheet:
• Hole diameter: 12 mm
• Min. hole depth: 90 mm
• Min. distance from edge: 105 mm
• Min. concrete thickness: 140 mm
• Tightening torque: 50 Nm
WARNING: Closely follow the original instructions of the
fastener manufacturer!
INSTALLATION ON STEEL STRUCTURE
Min. steel quality: S235JR
Indispensable premise is a statically stable substructure. If in doubt,
consult a calculation expert.
4x M12 stainless steel bolts with self-locking nut
Min. steel structure thickness: 6 mm
Hole diameter: 12.5 mm
Min. distance from edge: 20 mm
According to the roof structure, different fastening bolt lengths are
required. Use only M12 stainless steel bolts and buts to comply with
correct installation instructions (bolt thread protruding min. 2 mm
from nut)!
These materials are available at: Rotho Blaas srl –Via Dell' A dige 2/1
– 39040 Cortaccia (BZ) - www.rothoblaas.com
25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tower22Towera2

Tabla de contenido