EN
6.0 PARAMETERS
Non‐approved balances have 8 parameters that can be set by the user.
FUNCTION SECTION
See section 6.1
F1 UNT
F2 EL
See section 6.2
F3 SEr
See section 6.3
F4 oFF
See section 6.4
F5 IEC
See section 6.5
F6 CA
See section 6.6
F7 SEt
See section 6.7
tECH
Service agents only Technical parameters setting mode / factory setting
Approved balances have 5 parameters that can be set by the user.
FUNCTION
SECTION
F1 EL
See section 6.2
F2 SEr
See section 6.3
F3 oFF
See section 6.4
F4 SEt
See section 6.7
tECH
Service agents only Technical parameters setting mode / factory setting
6.1 ENABLING
You can enable and disable the weighing units available to the user when they press
the [Mode] key as described in section 4.4 Weighing Units.
1) To set this parameter press and hold the [Mode] key during self‐checking test
when turning on the balance.
2) After a few seconds, the display will show the first function F1 UNT.
3) Press the [‐>0/T<‐] key to view the current settings of each unit.
4) Pressing the [‐>0/T<‐] key will cycle through the other units along with their
current settings. For example, if oFF is displayed with the weighing unit Carats,
the user will not be able to use this unit while weighing.
© Adam Equipment Company 2018
DESCRIPTION
Sets the units to be used
/
g
/ N /g2.
Sets the backlight and audible alert beep
Sets the print parameters
Sets the auto power‐off parameter
Internal or external calibration select
Cal mass fine adjust
User Parameters for autozero, filter and stability
DESCRIPTION
Sets the backlight and audible alert beep
Sets the print parameters
Sets the auto power‐off parameter
User Parameters for autozero, filter and stability
WEIGHING
UNITS
ct / Lb / oz / d / GN / OZt / dWt / MM / TL.T / TL.C / TL.t /t
(
NOT APPROVED MODELS
(SW ver. 2.5 onwards)
(SW ver. 2.5 onwards)
)
14