Toilet And Flush Switch Installation - Dometic MASTERFLUSH MF7100 Instrucciones De Montaje Y De Uso

Inodoro triturador
Ocultar thumbs Ver también para MASTERFLUSH MF7100:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
• Discharge hose loop near toilet (not supplied with
toilet):
– To retain water in toilet bowl, make a 12 in.
(30 cm) high loop in discharge line as near to
toilet as possible (fig. 8, 9).
• Vented loop (not supplied with toilet):
– Refer to toilet system layout figures 9, 10, 11 for
recommended locations of discharge vented
loops connected to system components that are
below the water line or may be less than 8 in.
(20 cm) above highest possible water line at full
heel.
– Vented loops must be positioned a minimum of
8 in. (20 cm) above highest possible water line at
full heel.
8 .5 Toilet and flush switch
installation
1. Carefully unpack toilet, water supply hose, discharge
fitting and hardware fig. 1).
2. Place toilet in desired location on floor. If necessary,
rotate toilet so that macerator pump housing (fig. 2)
does not interfere with walls, or so that it will better
accommodate the intended plumbing layout.
Confirm adequate clearance is available for plumbing
connections, and also the seat and lid in raised
position. Mark floor where toilet will be installed.
3. (Optional) If macerator pump and base must be
positioned at an angle so that toilet bowl does not
face in correct direction, the upper bowl can be
rotated to the proper position:
12
14
13
a. Loosen compression band (fig. 12) just enough to
slip down past lower plastic clamp, and remove
upper and lower plastic clamps (fig. 13).
14
b. Lift bowl. Make sure notch in black rubber gasket
sits around shallow pin on toilet base and remains
centered between bowl and base (fig. 14). Rotate
bowl to desired position, then set it down on
gasket.
c. Re-position plastic clamps and compression
band between upper bowl and base. Join clamps
together at front of toilet bowl (there will be a
space between the clamps behind the bowl).
With compression band screw positioned on
a clamp (not in gap between clamps) (fig. 12),
tighten compression band to 65 in.-lbs.
4. Connect water supply hose between check valve
or adapter (fig. 2) and water valve (freshwater flush
model) or water pump (sea water flush model) on
base.
a. Cut supply hose to length that will not kink when
connected.
b. Remove plastic cover (fig. 2) from pump.
Macerator Toilet
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Masterflush mf7200

Tabla de contenido