Programming overview
3-9
Menu
Input
No.
Selection
item
Setting the gate in upper position
3
30
reverse direction (keep button pressed for 5 sec)
Setting the gate in lower position
31
Fine adjustment of upper end position
50*
33
0 - 50
0... 80mm deeper
50 - 99
0... 80mm higher
Fine adjustment of lower end position
50*
34
0 - 50
0... 80mm deeper
50 - 99
0... 80mm higher
Selection of edge safety device
measurement display (keep button pressed for 5 sec)
optical edge safety device OSE
0
35
electrical safety edge 8K2
1*
2
shockwave strip with testing
Selection of the light barrier
0*
without light barrier
1
2-wire light barrier LS2
2
4-wire light barrier Ls5, reflection light barrier
36
3
light barrier LS2 installed in the frame
4
Light barrier LS5, reflection light barrier, installed in the frame
5
4-wire light barrier with testing
6
4-wire light barrier installed in the frame with testing
Correction of the pre-limit switch for the edge safety
25*
37
0 - 25
0... 50mm deeper
25 - 99
0... 100mm higher
Finish menu
- -
Selection of the operating mode
4
0
dead-man OPEN/dead-man CLOSE
40
1
pulse OPEN/dead-man CLOSE
2*
pulse OPEN/pulse CLOSE
Status relay X3
0
gate closed message
1*
gate open message
2
warning during the drive
45
3
5 min light
4
wipe pulse with hand-held transmitter
5
wipe pulse
Finish menu
- -
Menu
30-
37
Item
1x
Menu
Input
No.
Selection
item
Opening force limitation
48
0*
off
1-30
input switch-off force
Power-on time for the motor
no limitation
0*
drive motor 5.24
1
drive motor 5.24 WS
2
49
drive motors 9.24
3
drive motor 9.24 WS
4
drive motor 14.15
5
Finish menu
- -
Functions of external command transmitter J1
5
0*
off
51
1
three-button control
pulse generator (OPEN-STOP-CLOSE function)
2
Service interface
off
53
0*
1
Service
Finish menu
- -
Teaching-in start button for the hand-held transmitter
60
6
Teaching-in light button for the hand-held transmitter
62
Deleting all function codes (keep button pressed for 5 sec)
63
Finish menu
- -
Pre-selection maintenance cycle for the gate
9
0*
no service interval
1
1 000 cycles
2
4000 cycles
3
8000 cycles
90
4
12000 cycles
5
16000 cycles
6
20000 cycles
7
25000 cycles
8
30000 cycles
Cycle counter output - cycles -
91
96
Operating hour counter output
97
Error memory output
98
Software output
Resetting the factory setting (keep button pressed for 5 sec)
99
Finish menu
- -
Enter
25 min/35%
25 min/30 %
25min / 60%
25min / 20%
25min / 60%
-
hours
-
-
hours error code
-
-
series number production dare -
* factory setting
Exit
-
-