Fitting the inverter
8
Fitting the inverter
8.1
Tools required
For the electrical connection you will need the following tools:
Crimping tool
3multi-coloured, flexible connection cables. Determine the necessary
thickness from the table in chapter chapter "Connecting the inverter" on
page 39.
Cable lugs and conductor sleeves
For fastening you will require the following tools:
Machine bolts (M4) with washers and self-locking nuts or
self-tapping screws or wood screws.
8.2
Mounting instructions
When selecting the installation location, observe the following instructions:
The inverter can be mounted horizontally or vertically.
The inverter must be installed in a place that is protected from moisture.
The inverter may not be installed in the presence of flammable materials.
The inverter may not be installed in a dusty environment.
The place of installation must be well ventilated. A ventilation system must
be available for installations in small, enclosed spaces. The minimum
clearance around the inverter must be at least 25 cm (fig. 2, page 3).
The air intake on the underside or the air outlet on the back of the inverter
must remain clear.
For ambient temperatures higher than 50 °C (such as in engine or heating
compartments, or direct sunlight), the heat from the inverter under load
can lead to automatic shutdown.
The device must be installed on a level and sufficiently sturdy surface.
38
SinePower
EN