Descargar Imprimir esta página

Toshiba Carrier RAS-15EK Manual De Instalación página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

Right
<_
Rear right
Bottom R ea
right left Bottom
left
1,Die-cutting
front
panel slit
With a pair of nippers,
cut out the slit on the leftward
or right side of the
front panel for left or right connection,
and the slit on the bottom
left or right
side of the front panel for bottom
left or right connection.
2, Changing
drain
hose
For leftward
connection,
bottom-leftward
connection
and rearleftward
connection's
piping,
it is necessary
to change
the drain hose and drain
cap.
How to remove
the
drain
hose
• The drain hose can be removed by removing the
screw securing the drain hose and then pulling out
the drain hose.
• When removing the drain hose, be careful of any
sharp edges the steel plate may have. Sharp
edges can cause injuries.
• To install the drain hose, insert the drain hose
firmly until the connection part contacts the heat
insulator, and then secure it with the original
screws.
Heat insulator
/
Drain hose
How to remove
the
drain
cap
Clip the drain cap with needle-nose
pliers and pull out.
How to fix the drain
cap
1) Insert a hexagon wrench
3/18 in. (4 mm) in the
center head of the cap.
2) Firmly insert the drain cap.
--
Do not apply lubricating
oil
(refrigerant
machine oil) when
inserting the drain cap. Application
Insert a hexagon
wrench 3/16 in.
causes deterioration
and drain
(4 ram).
leakage from the plug.
Bend the connecting
pipe within
a radius
of 1-3/16 in. (30 ram).
To connect the pipe after the unit has been installed (figure)
Outward form of indoor unit
If the pipe is bent incorrectly, the indoor unit may be unstable on the wall.
After passing the connecting pipe through the pipe hole, connect the
connecting pipes to the refrigerant line and wrap facing tape around them.
, Bind the refrigerant lines (two) and connecting cable with facing tape
tightly. In case of leftward piping and rear-leftward piping, bind the
refrigerant lines (two) only with facing tape.
- indoor unit
installation plate J
\_'L
.... F_
J
" Carefully arrange pipes such that none of them stick out of the rear
plate of the indoor unit.
• Carefully connect the refrigerant lines and connecting pipes to one
another and cut off the insulating tape wound on the connecting pipe
to avoid double-taping at the joint; moreover, seal the joint with vinyl
tape, etc.
• Check for gas leaks before insulating.
Firmly insert the drain hose and drain cap; otherwise, water may leak.
@
In case of right
.................................
• After making slits of the front panel with a
knife or a making-off pin, cut them with a
pair of nippers or an equivalent tool.
left piping
• After making slits of the front panel with a
knife or a making-off pin, cut them with a
pair of nippers or an equivalent tool.
• Bend the connecting pipe so that it is laid within 1-5/8 in. (43 mm) above
the wall surface. If the connecting pipe is laid exceeding 1-5/8 in. (43 mm)
above the wall surface, the indoor unit may be unstable on the walt.
When bending the connecting pipe, make sure to use a spring bender to
avoid crushing the pipe.
1. Pass the pipe through
the hole in the wall and hook the indoor
unit on the
upper hook of the installation
plate.
2. Swing
the indoor
unit to the right
and left to confirm
that it is firmly
hooked
up to the mounting
plate.
3. While
pressing
the indoor
unit onto the wall, hook it to the lower
section
of the mounting
plate.
Pull the indoor
unit toward
you to confirm
that it is
firmly hooked up to the mounting plate.
_/_-_-Hookh
....
/
. f('_)
Inst allat ion plate
Hook
, To detach the indoor unit from the
mounting plate, pull the indoor unit toward
you while pushing its bottom up as shown
in the figure.
Press
(unhook)
Push
Push
Due to piping
installation,
in some cases
the lower section
of the indoor unit may
not completely
attach
to the mounting
plate,
tn such a case, use the provided
screws
_
to fix the unit to the mounting
_4_ s ....
_
s ....
plate.
lO
1110651824-2
EN.indd
10