Disposal

9
Disposal
➤ Place the packaging material in the appropriate recycling waste bins
wherever possible.
If you wish to finally dispose of the device, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
10

Troubleshooting

Compressor does not run
Fault
U
= 0 V
T
≤ U
U
T
ON
Start attempt with
≤ U
U
T
OFF
Start attempt with
≥ U
U
T
ON
Electric circuit between
the pins in the
compressor interrupted
Voltage between the positive and negative electronic terminals
U
T
Switch-on voltage of the electronics
U
ON
Switch-off voltage of the electronics
U
OFF
(See table on page 25)
30
Possible cause
The connection between the battery
and the electronics is interrupted
Main switch defective (if installed)
Additional supply line fuse has blown
(if installed)
Battery voltage is too low
Loose cables
Poor contact (corrosion)
Battery capacity too low
Cable cross section too low
Ambient temperature too high
Insufficient ventilation
Condensor is dirty
Fan defective (if installed)
Defective compressor
HDC-190, HDC-220
Remedy
Establish a connection
Replace the main switch
Replace the fuse
Charge the battery
Establish a connection
Replace the battery
Replace the cable
(3, page 4)
Move the refrigerator
Clean the condensor
Replace the fan
Replace the compressor