SinePower
10.2
Status indications
"Input Level" LED(fig. 6 2, page 4 and fig. 7 2, page 5)
The "Input Level" LED shows the present range of the input voltage.
Display
Red, slow flash
Red
Orange
Green
Orange, flash
Red, quick flash
"Load Level" (fig. 6 3, page 4 and fig. 7 3, page 5)
The "Load Level" LED shows the power being supplied by the inverter.
Display
Off
Green
Orange
Red, slow flash
Red, quick flash
EN
MSI912, MSI1312,
MSI1812, MSI1812T
<10.6 V
10.6 – 11.0 V
11.0 – 12.0 V
12.0 – 14.2 V
14.2 – 15.0 V
>15.0
Input voltage
MSI 912,
MSI1312,
MSI924
MSI1324
0 – 80 W
80 – 320 W
320 – 720 W
720 – 800 W
1080 – 1200 W 1440 – 1600 W
>800 W
Using the inverter
Input voltage
MSI924, MSI1324,
MSI1824, MSI1824T
<21.2 V
21.2 – 22.0 V
22.0 – 24.0 V
24.0 – 28.4 V
28.4 – 30.0 V
>30.0
0 – 120 W
120 – 480 W
480 – 1080 W
640 – 1440 W
>1200 W
MSI1812,
MSI1812T,
MSI1824,
MSI1824T
0 – 160 W
160 – 640 W
>1600 W
53