Troubleshooting - Dometic GROUP WAECO SinePower MSI912 Instrucciones De Montaje

Convertidor de ondas seno
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89

Troubleshooting

12
Troubleshooting
!
WARNING!
Do not open the device. You risk sustaining an electric shock by
doing this.
I
NOTE
If you have detailed questions on the specifications of the in-
verter please contact the manufacturer (addresses on the back of
the instruction manual).
The "Load Status" LED (fig. 6 3, page 4 and fig. 7 3,page 5) lights up red
to indicate the fault:
LED display
Quick flash
Slow flash
Occasional flash
Constantly lit
56
Cause
Input voltage is too high
Input voltage too low
Overheating
Short circuit or reversed polar-
ity
Excessive load
Remedy
Check the input voltage and reduce
it.
The battery needs recharging.
Check the cables and connections.
Switch off the inverter and the con-
sumer.
Wait 5 to 10 minutes and switch the
inverter on again without any electric
consumers.
Reduce the load and make sure the
inverter has better ventilation. Then
switch the consumer back on.
Switch off the inverter and remove
the consumer.
Then switch the inverter back on
without the consumer. If no exces-
sive load is now shown, then there is
a short circuit in the consumer or the
total load was higher than the power
specified on the data sheet. MSI
1812T and MSI 1824T: The fuse in
the device must be pressed in again
by hand after it is triggered.
Check the cables and connections.