Technical Data - Dometic GROUP WAECO SinePower MSI912 Instrucciones De Montaje

Convertidor de ondas seno
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89

Technical data

15
Technical data
I
NOTE
In the event of thermal overloading, the inverter reacts by reduc-
ing the power for temperatures of 40°C and above.
If the temperature exceeds 60°C, the inverter switches off.
Item no.:
Rated input voltage:
Output power
at 25 °C for 10 min:
Peak output power:
Output voltage:
Output frequency:
Idle current consumption:
Standby current consump-
tion:
Input voltage range:
Efficiency up to:
Ambient temperature for
operation:
Ambient temperature for
storage
Priority circuit:
Dimensions W x D x H:
Weight:
58
MSI912
9102600111
12 V g
900 W
1600 W
200 – 240 Vw pure sine wave (THD < 3%)
50 or 60 Hz
1.8 A
0.5 A
10.5 V – 16 V
89 %
-20 °C to 40 °C
40 °C to 60 °C (reduced power)
-30 °C to +70 °C
230 V input protection: 10 A
Switchover time of bypass relay: < 30 m sec
197.5 x 94.3 x 291 mm, see fig. d, page 8
4 kg
SinePower
MSI924
9102600112
24 V g
1.0 A
0.3 A
21 V – 32 V
91 %
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido