Circuit board
connector plugs
Thermal
strip (2x)
15. Install NEW GASKET ONTO LENS: Stretch the gasket around the
circumference of the lens. Be sure the gasket is installed evenly around the
lens.
16. ALIGN LENS/GASKET ONTO LIGHT HOUSING:
a) With the light housing resting on its base, place the lens/gasket on top of the
light housing.
b) Rotate the lens/gasket to align the letter "W" ("WIDE" angle) on the lens with
the brass nut in the housing.
Note: The IntelliBrite light lens ships from the factory in the 'WIDE' (W) angle
position. To use the "NARROW" angle light beam, rotate the lens/gasket to align
the letter "N" on lens. Note: For more information about using the "WIDE" and
NARROW angle lens.
17. INSTALL FACE RING: Place the face ring on top of the lens/gasket/housing.
Rotate the face ring so the pilot screw hole is aligned in the 12 O'clock
position, with the lens letter "W" (or "N") and the brass nut in the housing. Also,
verify the "TOP" position arrow indicator label on the rear of the housing is
aligned with the pilot screw on the face ring.
Retaining nut (4x)
circuit board
Light housing
Circuit board
stud (4x)
17