3.
Using a #3 Phillips head screwdriver, loosen the CLAMP SCREW and
remove uni-tension wire clamp from the face ring.
4.
Remove the face ring and wire clamp from the light housing and set
aside for installation later.
Note: A 120 VAC to 12
VAC external transformer
is required for the 12 VAC
model IntelliBrite Spa light.
Note: The IntelliBrite Spa
Light fixture is a sealed light
assembly with no replaceable
circuit board assembly. Only
the lens, gasket and face
ring can be removed from
the sealed light assembly for
replacement.
5.
With the light assembly resting on its base, carefully pry off the gasket to
release the lens. Discard the gasket. A NEW LENS GASKET MUST BE
USED EACH TIME THE SPA LIGHT IS REASSEMBLED
6.
Disconnect the IntelliBrite Spa light assembly cord from the junction box.
Cut the cord near the back of the light assembly and discard the
light. See Spare Parts page for replacement instructions for the new
spa light.
Cut cable and discard
light assembly
Spa light assembly
Spa light fixture with lens, gasket
and face ring attached
Discard old
gasket
Lens
(keep
lens)
Phillips screw
Face ring and uni-
tension wire clamp
21
Loosen the
Phillips screw
to remove wire
clamp from
face ring