Electrical Data
Heater Watts
2500/2050
Voltage
Heating BTU/h
8500/7000
Heating Current (Amps)
Minimum Circuit Ampacity
Branch Circuit Fuse (Amps)
LRA - Compressor (Amps)
Cooling Current (Amps)
Basic heater Size
Power Connection
Recommended Branch
Circuit Wire Sizes
* AWG-American Wire Gauge

Electrical Requirements

Use ONLY wire size recommended for
Wire Size
single outlet branch circuit.
Use ONLY type and size fuse or HACR
circuit breaker indicated on unit's rating
plate (See sample below). Proper over
current protection to the units is the respon-
sibility of the owner.
Unit MUST be grounded from branch circuit
to unit, or through separate ground wire
provided on permanently connected units.
Be sure that branch circuit or general
purpose outlet is grounded.
Use recommended wire size given in tables
and install a single branch circuit. All wiring
must comply with local and national codes.
NOTE: Use copper conductors only.
NOTE: All field wiring must comply with NEC and local
codes. It is the responsability of the installer to insure that
the electrical codes are met.

Electrical Rating Table

NOTE: Use copper conductors ONLY. Wire sizes are per
NEC. Check local codes for overseas applications.
Recommended branch circuit wire sizes*
Nameplate maximum circuit breaker size
1
5
A
2
0
A
3
0
A
AWG --- American Wire Gauge
* Single circuit from main box.
** Based on 100' or less of copper, single insulated
conductor at 60° C
VHA09K
3400/2780
5000/4090
230/208
11600/9500 17000/13900
10.9/9.9
14.8/13.4
21.7/19.7
15
19.9
28.6
15
20
18.5
18.5
18.5
4.1/4.3
4.1/4.3
4.1/4.3
2.5 Kw
3.4 Kw
5.0 Kw
HARD WIRED
14
12
AWG Wire size**
1
4
1
2
1
0
VHA12K
2500/2050
3400/2780
230/208
8500/7000
11600/9500 17000/13900
10.9/9.9
14.8/13.4
15
19.9
30
15
20
26
26
5.3/5.5
5.3/5.5
2.5 Kw
3.4 Kw
HARD WIRED
10
14
12
Sample Nameplate
VHA18K
5000/4090
2500/2050
3400/2780
208/230
8500/7000
11600/9500 17000/13900
21.7/19.7
10.9/9.9
14.8/13.4
28.6
15
30
15
26
42
5.3/5.5
8.2/8.6
8.2/8.6
5.0 Kw
2.5 Kw
3.4 Kw
HARD WIRED
10
14
WARNING
Electrical shock hazard.
Turn OFF electric power before service
or intallation.
Unit must be properly grounded.
Unit must have correct fuse or circuit
breaker protection.
Unit's supply circuit must have the
correct wire conductor size.
All electrical connections and wiring must
be installed by a qualified electrician and
conform to the National Electrical Code
and all local codes which have jurisdiction.
Failure to do so can result in property
damage, personal injury and/or death.
5000/4090
21.7/19.7
19.9
28.6
20
30
42
42
8.2/8.6
5.0 Kw
12
10
120524