- Make electrical checkings of the electric panel and pressure switch regulation until
the operating error will be found
14. Check equipment stoppage by the tank level (lift up the buoy in order to indicate the
tank signal of the water level)
If the equipment stops:
- Lower the buoy again.
If the equipment does not stop:
- Make electrical checkings of the electric panel until you find the functioning error.
15. Leave the equipment working 10 minutes more.
16. If there is any flushing option:
- Press the manual flushing button.
- Check that the equipment does a flushing under normal conditions.
17. Stop the equipment.
18. Disconnect the equipment from water and power supplies (in case of power supply,
always disconnect the wiring with the thermomagnetic switch of the equipment turned
down and disconnected from the power supply. With water supplies close the inlet
valve first.
08 SINOPTIC CONTROL SCHEME.
Standard version 8040 serie only.
In the event that the equipment does not incorporate the synoptic panel with the
MICRO 810 programmable relay, see ANNEXE 5. CONTROL SYSTEM corresponding,
where the control of the system with OMRON automaton and the digital screen versions
PRIME, ADVANCE and ULTRA are specified.
General image of the synoptic panel located in the door of the electrical panel, where the
reverse osmosis system is represented with light signals and the operation of each
element at each moment of the equipment.