PUMP
***Make sure to have at least 1 inch [25MM]
of clearance from the sensors on the Ul-
tima Bilge pump to any wall or souround-
ings. If there is not enough clearance, the
sensors may detect the object and leave
the pump running continuously. * **
Maintenance:
The Ultima bilge pump is designed to be
worry free and maintenance free. How-
ever, care should be taken to make sure
that the impeller is clear of debris for opti-
mum pump functionality. Make sure power
is disconnected during maintenance of
the pump. To access the impeller, remove
pump from strainer by depressing the side
lock tabs on pump body and pulling pump
from strainer. To clean the impeller, grab on
to impeller guards fins and rotate impel-
ler guard clockwise and pull straight out.
Remove and clean the impeller and pump
from all debris that has accumulated. Make
sure to clean any debris that has accu-
mulated on the strainer as well. After the
impeller is clean, replace impeller guard
by aligning tabs with slots and turning
counter-clockwise, making sure not to over
tighten. The guard should be rotated until
it is firm. Place pump body on to strainer
making sure that both locking tabs snap
onto pump body.
Original instructions
Black to negative(-)
Brown to positive (+)
(Manual override)
Brown/white to positive (+)
(Automatic operation)
Depress
(2) tabs
Warranty Information
Johnson Pumps of America of 1625 Hunt-
er Road, Suite B, Hanover Park, Illinois
60133 warrants to the original consumer
purchaser that this product will be free
from defects in material and work manship,
providing that the case is not opened or
the pump other wise abused for a period
of three (3) years from the date originally
purchased.
> English
Lock impeller guard
by twisting counter
clockwise
9