Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

GENERAL WARNINGS AND SAFETY INFORMATION
IGNITION INSTRUCTIONS
• Inspect hose before each use. If there are signs of abrasion, wear, cuts, or leaks the hose must be replaced.
DO NOT USE.
• If unit is equipped with burner covers, remove covers. Never use burner covers during operation.
• Inspect burner before each use. Check burner and burner venturi tube for insects and insect nests. A clogged
tube can lead to a fire beneath unit.
• Check to ensure the orifice is centered inside the venturi tube. Failure to properly assemble the valve orifice to the
venture tube can result in gas leak or potential fire at connection. See assembly steps for proper assembly
method.
• Connect hose regulator to LP Gas Cylinder
1. Make sure gas cylinder valve is closed. Turn valve clockwise until it stops.
2. Make sure adjustable regulator on unit is in the OFF position.
3. Remove protective cap from gas cylinder and coupling nut if applicable.
4. Center and insert regulator nipple into valve outlet on gas cylinder as shown in figure on the left. Turn
regulator coupling nut clockwise until it stops. DO NOT OVER TIGHTEN.
• Perform soapy water test.
• Before starting lighting procedure make sure all cooking accessories and cooking vessels are removed from unit.
• When lighting burner remove all parts inside or on unit to prevent explosion from gas build up.
TO USE:
1. T urn gas cylinder valve on.
2. Turn adjustable regulator knob counter clockwise 1 full turn.
3. Turn timer on by pressing the power button on timer.
4. Press the red button to start the timer.
• This will allow gas flow for 15 minutes.
• You must continue to press the red button every
15 minutes so the flame does not go out.
5. If unit has an ignitor button, push ignitor button to light. If unit does
not have an ignitor button then follow match light instructions.
• If ignition does not take place within five seconds, turn adjustable regulator to OFF position and wait five minutes
and repeat lighting procedures. If ignition still does not occur, see match light directions below.
• If flame goes out during cooking, turn adjustable regulator OFF, turn gas cylinder valve OFF, remove any
cooking accessories or cooking vessels from unit and wait 5 minutes then repeat ignition instructions above.
• Adjustable regulator adjusts burner flame. Turn regulator knob clockwise to decrease flame. Turn valve counter
clockwise SLOWLY to increase flame. Turn regulator knob clockwise until it stops to shut flame off.
• Visually check burner flame. A CORRECT FLAME should be blue with a small amount of yellow at the tip. An
INCORRECT FLAME is excessively yellow and irregular. If an incorrect flame occurs, turn burner control valve to
OFF position, turn OFF regulator and gas cylinder valve. Allow unit to cool and then clean burner. Let burner
completely dry before re-lighting. Adjust the air shutter to the burner until the burner flame is as blue as possible,
see image below.
• After use turn burner control valve OFF, then turn gas cylinder valve OFF and disconnect tank.
• Type 1 regulators will have a hook as shown in image below. The regulator hook is used to keep the regulator
off the ground when removed from the LP cylinder. Attach to unit as shown in image.
Adjust air shutter to the burner until the
burner flame is as blue as possible
YELLOW
BLUE
CORRECT
INCORRECT
FLAME
FLAME

LOW BATTERY

START
TIMER
The regulator
hook is used
to keep the
regulator off the
ground when
CLOCKWISE
removed from the
LP cylinder. Attach
to appliance
ON
as shown.
GAS
FLOW
POWER
COUNTER
CLOCKWISE
OFF
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mb20020107

Tabla de contenido