CODE
ERROR NAME
X-Motor A Phase Defect Error
E-029
X-Motor B Phase Defect Error
E-030
Y-Motor A Phase Defect Error
E-031
Y-Motor B Phase Defect Error
E-032
USB system file error
E-034
Main Axis Overload
E-037
Main motor UVW sensor error
E-038
Main motor up positioning sensor error
E-039
Main motor down positioning sensor
E-040
error
Main motor encoder error
E-041
Main motor Z phase sensor error
E-042
Main motor U phase current offset
E-043
error
Main motor V phase current offset
E-044
error
Main Axis U Phase Defect Error
E-046
Main Axis V Phase Defect Error
E-047
Main Axis W Phase Defect Error
E-048
X Motor Encoder Error
E-053
Y Motor Encoder Error
E-054
PROBABLE CAUSE
-The connector of X-axis motor cable has not been firmly inserted.
-X-axis motor cable has been disconnected.
-The connector of X-axis motor cable has not been firmly inserted.
-X-axis motor cable has been disconnected.
-The connector of Y-axis motor cable has not been firmly inserted.
-Y-axis motor cable has been disconnected.
-The connector of Y-axis motor cable has not been firmly inserted.
-Y-axis motor cable has been disconnected.
-System file in the USB memory is broken.
-The load torque of the sewing machine is too large.
-The connector of the main motor has not been firmly inserted.
-The signal from the main motor encoder has been disconnected.
-The connector of the main motor has not been firmly inserted.
-The signal from the main motor encoder has been disconnected.
-The connector of the main motor has not been firmly inserted.
-The signal from the main motor encoder has been disconnected.
-The connector of the main motor has not been firmly inserted.
-The signal from the main motor encoder has been disconnected.
-The connector of the main motor has not been firmly inserted.
-The signal from the main motor encoder has been disconnected.
-There is a trouble in the U-phase current sensor on the XC-B substrate.
-There is a trouble in the V-phase current sensor on the XC-B substrate.
-Wiring to the main motor has been disconnected.
-Wiring to the main motor has been disconnected.
-Wiring to the main motor has been disconnected.
-X-axis encoder connector has not been firmly inserted.
-The signal from X-axis encoder has been disconnected.
-Y-axis encoder connector has not been firmly inserted.
-The signal from Y-axis encoder has been disconnected.
-Check insertion of the connector.
-Check the wiring of the cable.
-Check insertion of the connector.
-Check the wiring of the cable.
-Check insertion of the connector.
-Check the wiring of the cable.
-Check insertion of the connector.
-Check the wiring of the cable.
-Check the system file in the USB memory.
-Check the sewing machine.
-Check insertion of the connector.
-Check the UVW phase signal by using IN/OUT setting mode.
-Check insertion of the connector.
-Check the UP signal by using IN/OUT setting mode.
-Check insertion of the connector.
-Check the DN signal by using IN/OUT setting mode.
-Check insertion of the connector.
-Check the A/B phase signal by using IN/OUT setting mode.
-Check insertion of the connector.
-Check the Z phase signal by using IN/OUT setting mode.
-Please exchange XC-B substrate.
-Please consult the sewing machine agent.
-Please exchange XC-B substrate.
-Please consult the sewing machine agent.
-Check wiring of the main motor.
-Check wiring of the main motor.
-Check wiring of the main motor.
-Check insertion of the connector.
-Check the XA/XB phase signal by using IN/OUT setting mode.
-Check insertion of the connector.
-Check the YA/YB phase signal by using IN/OUT setting mode.
160