Electrical Connection; Current Carrying Capacity Of The Inputs And Outputs - Miele professional XCI-Box-LG Instrucciones De Manejo

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
en - English

Electrical connection

The XCI box is supplied with mains
voltage by the Miele Professional ma-
chine.
The XCI box does not have an addi-
tional On/Off switch.
Damage to the XCI box due to
incorrect connection.
Excess current can damage the XCI
box.
The XCI box must not be connected
to an external voltage.
Technical data
Voltage
Frequency
Temperature
range for operation
Current carrying capacity of
the inputs and outputs
During installation, make sure that
the current consumption of the addi-
tional components to be connected
does not exceed the permissible in-
dividual currents and total current
consumption in the neutral con-
ductor.
During installation, make sure that
connecting the washing machine/
tumble dryer in combination with the
XCI box and the associated hard-
ware does not exceed the total fuse
rating of the electricity supply.
36
200 V–240 V
50 Hz/60 Hz
2 °C–35 °C
The inputs and outputs are designed
specifically for currents, as described in
section "Current carrying capacity ta-
ble".
The switching element for contact 3.3 is
designed in such a way that a fan and
frequency converter can be connected.
When connecting external hardware
provided by other manufacturers, the
cable cross-section must not be less
2
than 1.0 mm
with a maximum cable
length of 2.50 m.
Empty sensor
The empty sensor is connected to
terminals 4.1 and 4.2. These meet
safety extra-low voltage requirements
(class III).
The specifications of the sensor
manufacturer must be observed.
The cables must be routed separ-
ately from all other cables.