Simer 3305P Manual Del Usuario página 4

Bombas convertibles tipo "jet" para pozos profundos
Ocultar thumbs Ver también para 3305P:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Replacing an Existing Pump
4
DEEP WELL
I_WARNINGIHazardous voltage. Disconnect power to
pump before working on pump or motor.
1. Drain and remove the old pump. Check pipe for
scale, lime, rust, etc., and replace
it if necessary.
2. Install the control
valve and pressure gauge in the
pump body (see Figure 1).
Figure l: install Control Valve and Gauge
.
If your old pump has the suction pipe (the larger port
- see Figure 2) below the drive port, you will need to
install flexible pipe between the well head and the
pump so that the connection will be correct. (See
Figure 3).
Piping
omitted
for clarity
NOTICE: Your old ejector (in the well) may not be
properly matched to your new pump. If the pump
does not perform properly, we recommend that you
install ejector kit FP4800 or 29660.
4. Install the pump in the system. Make sure that all pipe
joints in the suction pipe are air-tight as well as water
tight. If the suction pipe can suck air, the pump will not
be able to pull water from the well.
5. Adjust the pump mounting height so that the plumbing
connections do not put a strain on the pump body.
Support the pipe so that the pump body does not take
the weight of piping or fittings.
You have just completed the well plumbing for your
new deep well jet pump. Please go to Page 8 for
discharge pipe and tank connections.
SHALLOW
WELL
[_WARNING IHazardous voltage. Disconnect power to
pump before working on pump or motor.
I.
2.
3.
Drain and remove the old pump. Check the old pipe
for scale, lime, rust, etc., and replace it if necessary.
Install the control valve and pressure gauge in the
pump body (see Figure 1).
Install ejector kit FP4875 or 29650 (kits are sold sepa-
rately). Follow the instructions provided with the kit.
Be sure to align the venturi with the top hole on the
front of the pump (see Figure 4).
NOTICE: Always replace the ejector when replacing
the pump in a shallow well installation.
Drive Pipe
_
t1"
sends water
down
the well
_
t1"
to drive water
_
ff
up through
the
_tf
Suction
Pipe
to Pump
Suction
2175 1295
Figure 2: Drive and Suction
Functions
If well
head
and pump
don't
match,
twist
reinforced
flexible
pipe
to connect
drive
and suction
pipes.
/
Drive
Suction
Pipe
Pipe
Figure 3: Reversed
Connections to Well
Figure 4: Mount
Ejector
- Shallow
Well
4. Install the pump in the system. Make sure that all pipe
joints in the suction pipe are air-tight as well as water
tight. If the suction pipe can suck air, the pump will not
be able to pull water from the well.
5. Adjust the pump mounting height so that the plumbing
connections do not put a strain on the pump body.
Support the pipe so that the pump body does not take
the weight of piping or fittings.
You have just completed the well plumbing for your
new shallow well jet pump. Please go to Page 8 for
discharge pipe and tank connections.