Descargar Imprimir esta página

KEY 900SEZ Manual De Instrucciones página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
*+&$, ',%%!'-,*
The CT-24S unit is compatible with the following Keyautomation receivers of the MEMO snap-in series:
900RXI-41 / 900RXI-41R / 900RXI-42 / 900RXI-42R
CABAT-30 BATTERY CHARGER (optional)
A system with the CT-24S can operate even if there is a mains power outage. Two batteries must be
installed, 12 V 1.3Ah. MAX (not included) and a CABAT-30 battery charger. All of this can be done without
making any modifications to the system.
For new systems, after installation and testing, insert the snap-in battery charger module in the
corresponding connector. Make sure the polarity of the two connecting cables on the batteries is correct.
Connection sequence:
Disconnect the 230 V AC power supply
Snap in the CABAT30 module
Connect the two batteries in series. Make sure the polarity is correct
Check that the safety LED' s come on
Re-connect the mains power supply
New batteries charge up after about ten hours.
The number of operations that can be performed under battery power depends on a number of factors. As
an example, consider 4 complete cycles in the following conditions:
sectional garage door of 10 m
system with 1 pair of photocells, snap-in receiver and 1 flasher (20W max.)
batteries charged
within 5 hours of 230V power supply failure
*! ,-! *!/!+ !
Install the device for the activation of the manual release at a height of less than 1.8 m and any fixed control
in view of the door but far from moving parts at a height greater than 1.5 m.
900SBCO
The sheath must be fastened so as to prevent the
creation of tight curves or corners. It can be adjusted
with the regulator (B). The bracket must be attached
over the opening handle of the door and the metallic
cable is to be secured to the lock
2
Insert the metal cable through the release handle,
and insert the aluminium sphere through the hole in
the plastic carriage
>
2
@

Publicidad