WARNING: In order for the machine to work correctly, the values of the said constants should not be altered.
IMPORTANT: ANY MACHINE MODEL WITH TWO BOILERS MUST NEVER HAVE THE
'Pressure Switch' OPTION SELECTED, AS THE MACHINE WORKS WITH A TEMPERATURE
SENSOR IN ORDER TO CONTROL THE COFFEE BOILER TEMPERATURE.
-
If 'On/Off ' is selected, press the MENU button to confi rm, and the display will show:
With the UP/DOWN buttons, select the unit of measurement for temperature, in Celsius (ºC) or in Fahrenheit (ºF).
Confi rm by pressing OK and immediately the display will show:
Press the UP/DOWN buttons to select the desired hysteresis (the variation in degrees for the temperature in the
specifi c boiler).
Confi rm by pressing OK key and immediately the display will show:
Press the UP/DOWN buttons to select the desired boiler temperature, and confi rm the selection by pressing OK.
-
If 'PID' is selected, press the MENU button to confi rm, and the display will show:
With the UP/DOWN buttons, select the unit of measurement for temperature, in Celsius (ºC) or in Fahrenheit (ºF).
Confi rm by pressing OK and immediately the display will show:
Press the UP/DOWN buttons to select the desired boiler temperature, and confi rm the selection by pressing OK.
The visual display will show:
Using the UP/DOWN buttons, select the value for each constant and confi rm by pressing OK. (IT IS RECOMMENDED
THAT THOSE VALUES ESTABLISHED BY THE MANUFACTURER BE MAINTAINED.)
The visual display will show:
Initial regulation temperature for the algorithm for the three constants. (It could have a value of '2ºC / Up to
20ºC' or '3ºF / Up to 36ºF'). (IT IS RECOMMENDED THAT THOSE VALUES ESTABLISHED BY THE MANUFACTURER BE
MAINTAINED.)
Press the UP/DOWN buttons to select the desired temperature, and confi rm by pressing OK.
INSTALLATION AND OPERATION MANUAL
Temperature
ºC / ºF
Histe. Temp.
xxxxxxx
Boiler Temperature
xxx ºC / xxxx ºF
ºC / ºF
Boiler Temperature
xxx ºC / xxxx ºF
KP KI KD
xxx xxx xxx
PID setting
0.5ºC
Xxxxxxx
1ºC
2ºC
IBERITAL
1ºF
2ºF
4ºF
Page 77