To remove the pre-motor filter:
1.
Remove the Dust Container from the cleaner mainbody. [14]
2.
Hold the Dust Container with one hand, press the pre-motor filter frame release
button and remove the pre-motor filter from the frame. [16]
Gently tap and wash the filter packs using hand warm water. [19] Remove excess
3.
water from the filters with a dry cloth and leave to dry fully before re-using.
4.
Reassemble filter packs once fully dry and refit to the cleaner.
IMPORTANT: Do not use the product without the pre-motor filter pack fitted.
IMPORTANT: Always ensure the filter packs are fully dry before use.
To access the exhaust filter:
1.
Unlock the exhaust filter cover by pressing the button and pull outward from main
cleaner.
2.
Remove the filter pack from the recess by pressing the locking mechanism clips on
the end of the filter inwards. [18]
3.
Gently tap and wash the filter pack using hand warm water. Do not use hot water or
detergents. [19] Remove excess water from the filters with a dry cloth and leave to
dry fully before re-using.
4.
Reassemble filter packs once it is fully dry and refit to the cleaner.
5.
Lock the exhaust filter cover by pressing the edge which has the clips, you will hear
a click once the exhaust filter door fits into place.
IMPORTANT: Do not use the product without the filter pack fitted.
Removing a blockage from the system
If the bag check indicator is red:
1
. Check if the dust container is full. If so refer to 'Emptying The Dust Container'.
2.
If the dust container is empty, but suction is still low:
A. Do the filters need cleaning? If so refer to 'Cleaning the Washable Filters'.
B. Check if there is any other blockage in the system - Use a rod or a pole to remove
any blockage from the tubes or hose.
C. Check if pre-motor filter is fitted.
D. Check for and clear any blockage in the nozzle.
E. Check for blockage of cyclone and clean if required.
WARNING: - If the cleaner is used for a significant period of time with a blockage, a
thermal cut out will switch the cleaner off to prevent overheating. If this should happen,
switch the cleaner off, unplug and correct the fault. It will take about 45 minutes for the
cut out to automatically reset.
ACCESSORIES AND NOZZLES
To obtain the best performance and energy efficiency#1 it is recommended that the
correct nozzles are used for the main cleaning operations. These nozzles are indicated
in the diagrams by the letters GP, HF or CA.
A nozzle type GP can be used to clean both carpet and hard floor.
A nozzle type HF is suitable for use only on hard floor.
A nozzle of type CA is suitable for use only on carpet.
The other nozzles are accessories for specialist cleaning tasks and are recommended
for occasional use only.
It is important to note that this vacuum cleaner is supplied with an Energy Label as re-
quired by European Regulation (EU) 665/2013.
If the label shows a red prohibition circle on the left covering the carpet symbol, then this
indicates that the vacuum cleaner is not suitable use on carpets.
If the label shows a red prohibition circle on the right covering the hard floor symbol, then
this indicates that the vacuum cleaneris not suitable for use on hard floors.
#1
NOTE: Dust pick up ability carpet, dust pick up ability hard floor, and energy efficiency
in accord with Commission Regulations (EU) 665/2013 and (EU) 666/2013.
Please see the model specification on the packaging label for inclusion of accessories to
individual models.
All accessories can be fitted to the hose handle or the end of the telescopic tube.
•
2 in 1 accessory – For corners and hard to reach areas and bookshelves, frames,
keyboards and other delicate areas [Q]. Remove the 2in1 accessory from the rear of the
cleaner [11] and fit onto the end of the handle. [12]
•
Parquet Nozzle**– For parquet floors and other delicate floors. [Z1, Z2]
•
Pet Hair Remover Mini Turbo Nozzle* - Use the mini turbo nozzle on stairs or for
deep cleaning on textile surfaces and other hard to clean areas. Particularly suitable for
pet hairs removal. [W]
•
Allergen Remover Mini Turbo Nozzle* – Use the mini turbo nozzle on stairs or for
deep cleaning on textile surfaces and other hard to clean areas. Particularly suitable for
allergen removal. [X]
Grand Turbo Nozzle* – Use the Grand Turbo Nozzle for deep cleaning on carpets. [Y]
•
IMPORTANT: Do not use the Grand Turbo Nozzle or Mini Turbo Nozzles on rugs with long
fringes, animal hides and carpet pile deeper than 15mm. Do not keep the nozzle stationary
while the brush is rotating.
USER CHECK LIST
should you have a problem with the product, complete this simple user checklist before
calling your local HOOVER service.
•
Is there a working electricity supply to the cleaner? Please check with another
electrical appliance.
•
Is the dust bag over-filled? Please refer to 'Cleaner Maintenance'.
•
Is the filter blocked? Please refer to 'Cleaner Maintenance'.
•
Is the hose or nozzle blocked? Please refer to 'Removing a blockage from the system'.
•
Has the cleaner overheated? If so, it will take approximately 45 minutes for the cut
out to automatically reset.
3
*Certain Models Only
GB
**Nozzle design may vary according to models