LG TROMM DLE5955W Instrucciones De Instalación página 15

Ocultar thumbs Ver también para TROMM DLE5955W:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATIONINSTRUCTIONS
VENTING THE DRYER (cont.)
Ductwork
0
65 ft. (19.8 m)
45 ft. (13.7 m)
Recommended
1
55 ft. (16.8 m)
35 ft. (10.7 m)
2
47 ft. (13.7 m)
30 ft. (9.1 m)
3
36 ft. (11.0 m)
25 ft. (7.6 m)
/_02o,nl
/_02oml
4
28 ft. (8.5 m)
20 ft. (6.1 m)
Use Only for Short
0
55 ft. (16.8 m)
35 ft. (10.7 m)
Run Installations
1
47 ft. (13.7 m)
27 ft. (8.1 m)
2
41 ft. (12.5 m)
21 ft. (6.4 m)
3
30ft.
(9.1 m)
17ft. (5.2 m)
/........,
4
22 ft. (6.7 m)
_../
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended
to use more than four 90 ° elbows.
Routing and Connecting
Ductwork
Follow the guidelines below to maximize drying
performance
and reduce lint buildup and
condensation
in the ductwork.
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
• Use 4-in. (10 cm) diameter rigid or semirigid
metal ductwork.
• The exhaust duct run should be as short as
possible.
• Use
as few
elbow
joints
as possible.
The male
end of each
section
of exhaust
duct
must
point
away
from
the
dryer.
Use
duct
tape
on all duct
joints.
Insulate
ductwork
that
runs
through
unheated
areas
in order
to reduce
condensation
and
lint
buildup
on duct
surfaces.
iMPORTANT:
Failure
to exhaust
the
dryer
correctly
will
void
the
dryer's warranty.
Correct
Venting
incorrect
Venting
15