Overview
10.3. Installation settings.
Re-access the installation's different settings:
• Date and time
Set the day and confirm. Proceed in the same way for the month, the year, the hour and the minutes.
Validate or not the automatic time change
• Operating ranges
This setting defines the authorised start-up ranges for the heat pump, the electric back-up and, if present, the
hydraulic back-up, based on the hot water requirements:
Permanent 24h/24h
Programming
• Language
Can be set to French, English, Dutch, Spanish, Portuguese, German, Italian and Polish.
10.4. The settings to adjust during installation.
❶ Press and hold
• Air ducts (aeraulic operation):
This setting defines the type of aeraulic connection made:
Interior/Interior
Exterior/Exterior
Interior/Exterior
• Installation (for products with coil):
Thermodynamics only
Boiler backup
Solar backup
In "Boiler backup", you are next asked to define a preference concerning the priorities of operation between
the boiler and the heat pump according to 4 levels:
The backup will only be active at the end of heating for very low air temperatures (<7° C)
Heat pump priority
The backup will only be active at the end of heating and ± earlier depending on the air
Heat pump optimised
temperature The heat pump is active at the start of heating and ± later depending on the air temperature
Boiler optimised
The heat pump is active at the start of heating and for air temperatures > 10 ° C.
Boiler priority
66
Installation
Start-up at any time of the day,
Start-up only within the programmed period.
1st range duration: 4 hours < time < 14 hours;
Total duration of the 2 ranges: 8 hours minimum and 14 hours maximum.
The settings are accessible in INSTALLER MODE
Hold down the MENU button and turn the dial a half turn to the right.
To exit the installer mode, proceed in the same way or wait 10 minutes.
Make a
Access settings
1/2 turn
to the
right
Suction and discharge not connected to air ducts (ambient air)
Suction and discharge connected to air ducts (ducted air)
Discharge connected to an air duct (semi-ducted)
The internal heat exchanger is not used
The internal heat exchanger is connected to a boiler controlled by the product
The internal heat exchanger is connected to a solar system
Use
Maintenance
+
Warranty
Settings