5. MAINTENANCE
5.1 - The cable is to be regulary checked for
wear (ie: kinks, single strund breakage). Faulty
cables must be replaced immediately. Do not
use the elevator tower with faulty cables.
Only use handle cables DIN 3060.
5.2 - The elevator tower has been lubricated in
the workshop. It is nevertheless recommended
that oil is regulary applied to the gear drive, the
bearing bushes on the drive shaft and to the
drum hub, the thread of the handle and the
profiles of the tower.
ATTENTION:
Do not apply oil or grease to the brake
mechanism.
The brake washers have been
pregreased with an special warmth and
pressure resistant grease. Do not use other
greases as this will effect the winch brake
performance.
It is not necessary greasing the brake
washers.
5.3 - The elevator tower TE-03 must be
inspected by trained personnel at least once
annually.
5.4 - In order to maintain this guarantee of
function and safety, original parts of the
manufacturer's design must be used.
The user forfeits all rights to claim if parts
other than those of the manufacturer are used
or modifies the product in any other way.
5.5 - When any spare part would be required,
it is necessary to indicate its reference number,
wich is included in the spare part of this
manual.
-