Adhere the seal 7 x 2 mm (item 3) to the flange of the adapter (item 6). Do not
glue over the holes.
Screw the adapter (item 6) with 6 screws M6 (item 5) to the flange of the
centrifugal fan (item 4).
Insert the sound absorber (item 1) into the round opening of the adapter
(item 6)
Screw the sound absorber (item 1) with 4 drilling screw (item 2) to the
circumference of the adapter (item 6).