GE Mentor Visual iQ Manual Del Usuario página 109

Ocultar thumbs Ver también para Mentor Visual iQ:
Tabla de contenido

Publicidad

SPECIFICATIONS
SPECIFICATIONS
Measurement Tip Optic Specs and Part Numbers for Mentor Visual iQ
Measurement Tip Optic Specs and Part Numbers for Mentor Visual iQ
Mentor Visual iQ 4.0 mm Tips
Mentor Visual iQ 4.0 mm Tips
3D Stereo Measurement and Stereo Measurement Tips
3D Stereo Measurement and Stereo Measurement Tips
Part No.
Part No.
Color
Color
TM405555FG
TM405555FG
Black
Block
TM405555SG
Blue
TM405555SG
Blue
Mentor Visual iQ 6.1mm Tips
Mentor Visual iQ 6.1mm Tips
3D Phase Measurement Tips
3D Phase Measurement Tips
XL4TM61105FG (forward
XL4TM61105FG
Black
Black
version)
(forward version)
XL4TM61105SG
XL4TM61105SG
Blue
Blue
(Side version)
(side version)
XL4TM61105FN-8651
Orange
XL4TM61105FN-8651
Orange
3D Stereo Measurement and Stereo Measurement Tips
3D Stereo Measurement and Stereo Measurement Tips
XLG3TM616060FG
XLG3TM616060FG
Black
Black
XLG3TM615050SG
Blue
XLG3TM615050SG
Blue
Mentor Visual iQ 8.4mm tips
Mentor Visual iQ 8.4mm tips
3D Stereo Measurement and Stereo Measurement Tips
3D Stereo Measurement and Stereo Measurement Tips
XLG3TM846060FG
Black
XLG3TM846060FG
Black
XLG3TM846060SG
XLG3TM846060SG
Blue
Blue
Measurement Software Part Numbers
Measurement Software Part Numbers
3D Stereo Measurement
3D Stereo Measurement
MVIQ-3DPM
MVIQ-3DPM
3D Phase Measurement
MVIQ-3DST
3D Phase Measurement
MVIQ-3DST
Stereo Measurement
MVIQ-ST
Stereo Measurement
MVIQ-ST
Projected Plane Measurement
MVIQ-PPM
Projected Plane Measurement
MVIQ-PPM
Area Depth Profile
Area Depth Profile
MVIQ-ADP
MVIQ-ADP
20
05/2018
FOV (deg)
FOV (deg)
DOF mm
DOF mm
55/55-FWD
55/55-FWD
5-inf
5-inf
55/55-SIDE
4-inf
55/55-SIDE
4-inf
105
8-250
105
8-250
105
7-250
105
7-250
105
3-120
105
3-120
60/60-FWD
60/60-FWD
4-80
4-80
50/50-SIDE
2-50
50/50-SIDE
2-50
60/60-FWD
4-50
60/60-FWD
4-50
50/50-SIDE
60/60-SIDE
4-50
4-50
3D Perspective Lines – Dotted blue lines showing the four corners
3D Perspective Lines – Dotted blue lines showing the four corners
of the tip field of view in the full image point cloud to help the user
of the tip field of view in the full image point cloud to help the user
understand and improve tip orientation relative to a surface. May
understand and improve tip orientation relative to a surface. May be
be shown or hidden via the settings menu.
shown or hidden via the settings menu.
3D Phase Measurement – A measurement technology that projects
3D Phase Measurement – A measurement technology that projects
line patterns on an object via a series of LEDs. Measurements are
line patterns on an object via a series of LEDs. Measurements are
calculated using the concept of phase shift analysis combined with
calculated using the concept of phase shift analysis combined with
(in)
(In)
proprietary processing technology.
proprietary processing technology.
(.20-inf)
(.20-inf)
3D Point Cloud – A 3D graphical representation of the surface being
3D Point Cloud – A 3D graphical representation of the surface being
(.16-inf)
(.16-inf)
inspected with lines and spheres added to show measurements
inspected with lines and spheres added to show measurements
made on that surface. The 3D point cloud can be rotated and viewed
made on that surface. The 3D point cloud can be rotated and viewed
from multiple angles and perspectives. It allows an inspector to check
from multiple angles and perspectives. It allows an inspector to check
the setup of their measurement and cursor placement points.
the setup of their measurement and cursor placement points.
3DPM Range Guide – Visual aid displayed when viewing live video
3DPM Range Guide – Visual aid displayed when viewing live video
with a 3DPM tip attached to indicate the system's ability to achieve
with a 3DPM tip attached to indicate the system's ability to achieve
(.31-9.84)
sufficient brightness with the tip LEDs for a high-quality scan.
sufficient brightness with the tip LEDs for a high-quality scan.
(.31-9.84)
Increasing the number of bars by moving closer to the target will
Increasing the number of bars by moving closer to the target will
increase 3D data quality and measurement accuracy.
increase 3D data quality and measurement accuracy.
(.27-9.84)
(.27-9.84)
3D Stereo Measurement – Uses the same optical principles
3D Stereo Measurement – Uses the same optical principles
(.12-4.72)
as Stereo Measurement and combines these with the ability to
(.12-4.72)
as Stereo Measurement and combines these with the ability to
create, manipulate and analyze a 3D Point Cloud representation of
create, manipulate and analyze a 3D Point Cloud representation of
measurement data.
measurement data.
Active Cursor – The cursor currently being manipulated, indicated
Active Cursor – The cursor currently being manipulated, indicated by
by a blue circle.
a blue circle.
(.16-3.15)
(.16-3.15)
(0.8-1.97)
(0.8-1.97)
Advisory Message – "For best results the reference cursors should
Advisory Message – "For best results the reference cursors should
be on the same plane" – In depth profile measurement, indicates the
be on the same plane" – In depth profile measurement, indicates the
reference cursors are not on the same plane.
reference cursors are not on the same plane.
Advisory Message – "Move closer to target or move cursors for better
Advisory Message – "Move closer to target or move cursors for better
results" – Indicates that the measurement is too small to be reliable
results" – Indicates that the measurement is too small to be reliable
at the current tip to target distance. Can be remedied by moving tip
at the current tip to target distance. Can be remedied by moving tip
closer to the indication or selecting larger measurement area.
(.16-1.97)
closer to the indication or selecting larger measurement area.
(.16-1.97)
(.16-1.97)
(.16-1.97)
CSV – Comma separated value, used for point cloud file data export.
CSV – Comma separated value, used for point cloud file data export.
Can be opened in a CAD package.
Can be opened in a CAD package.
Depth Assist – Feature wherein the the system searches the surface
Depth Assist – Feature wherein the the system searches the surface
data in the vicinity of the first three cursors of a Depth measurement
data in the vicinity of the first three cursors of a Depth measurement
and automatically places the fourth cursor at the deepest point,
and automatically places the fourth cursor at the deepest point,
highest point, or a point on a blade tip saving the user the time of
highest point, or a point on a blade tip saving the user the time of
locating those points manually.
locating those points manually.
Depth Map – 3D point cloud viewing mode in which either the tip to
Depth Map – 3D point cloud viewing mode in which either the tip to
target distance (full image) or the perpendicular distance from the
target distance (full image) or the perpendicular distance from the
measurement reference plane (measurement image) is color coded
measurement reference plane (measurement image) is color coded
to provide better understanding of 3D data noise levels and surface
to provide better understanding of 3D data noise levels and surface
contours.
contours.
Depth Profile View – Alternative 2D view of depth profile along a
Depth Profile View – Alternative 2D view of depth profile along a
selected depth profile line.
selected depth profile line.
Edge View Angle (EVA) – Displayed next to the MTD to help the user
Edge View Angle (EVA) – Displayed next to the MTD to help the user
gauge the suitability of the viewing perspective when making a Point
gauge the suitability of the viewing perspective when making a Point
to Line, Depth, or Area measurement near the edge of a surface using
to Line, Depth, or Area measurement near the edge of a surface using
a Measurement Plane.
a Measurement Plane.
Edge View Angle Line (EVA Line) – Line shown in the point cloud
Edge View Angle Line (EVA Line) – Line shown in the point cloud
indicating where the EVA is determined. The EVA is 0° when the EVA
indicating where the EVA is determined. The EVA is 0° when the EVA
Line is perpendicular to the measurement plane.
Line is perpendicular to the measurement plane.
Glossary
Glossary
FOD – Foreign Object Damage.
FOD – Foreign Object Damage.
Full Image Point Cloud – Shows all measurements and surface data.
Full Image Point Cloud – Shows all measurements and surface data.
The depth map indicates the distance from the measurement tip to
The depth map indicates the distance from the measurement tip to
the surface.
the surface.
Guide Lines – Lines shown in the point cloud views when using a
Guide Lines – Lines shown in the point cloud views when using a
Measurement Plane with Length, Point to Line, Multi Segment, or Area
Measurement Plane with Length, Point to Line, Multi Segment, or Area
to help the user position cursors to align with out-of-plane surface
to help the user position cursors to align with out-of-plane surface
points.
points.
InspectionWorks Connect – Remote collaboration tool allowing live
InspectionWorks Connect – Remote collaboration tool allowing live
remote viewing of inspection video, two–way chat and annotation.
remote viewing of inspection video, two–way chat and annotation.
Can be activated directly on the Mentor iQ handset.
Can be activated directly on the Mentor iQ handset.
Inactive Cursor – Cursors not currently selected, indicated by a green
Inactive Cursor – Cursors not currently selected, indicated by a green
circle.
circle.
Inspection Manager – PC–based re-measurement tool for visual
Inspection Manager – PC–based re-measurement tool for visual
inspection images.
inspection images.
Measurement Image Point Cloud – Shows only the active
Measurement Image Point Cloud – Shows only the active
measurement and surface data in its vicinity. The depth map
measurement and surface data in its vicinity. The depth map
indicates the perpendicular distance of the surface points from the
indicates the perpendicular distance of the surface points from the
measurement's reference plane.
measurement's reference plane.
Missing Corner – The corner of a turbine blade that has been broken
Missing Corner – The corner of a turbine blade that has been broken
off usually by a foreign object passing through the turbine.
off usually by a foreign object passing through the turbine.
MTD – Maximum target distance. Identifies the distance of the
MTD – Maximum target distance. Identifies the distance of the
furthest cursor point in a given measurement from the tip of the
furthest cursor point in a given measurement from the tip of the
probe.
probe.
Noise in the Point Cloud – Artifacts in the 3D data not representative
Noise in the Point Cloud – Artifacts in the 3D data not representative
of true surface geometry. Noise is generally reduced by moving the
of true surface geometry. Noise is generally reduced by moving the
tip closer to the target surface or changing angle of approach to
tip closer to the target surface or changing angle of approach to
reduce reflections.
reduce reflections.
Orange Outline Around Measurement Results and MTD Value
Orange Outline Around Measurement Results and MTD Value –
– Indicates that the measurement is too small to be reliable for the
Indicates that the measurement is too small to be reliable for the
current tip to target distance. Can be remedied by moving tip closer
current tip to target distance. Can be remedied by moving tip closer
to measurement or selecting larger measurement area.
to measurement or selecting larger measurement area.
Profile Slices – Paths along the surface between the reference
Profile Slices – Paths along the surface between the reference
profile lines in an Area Depth Profile Measurement that map
profile lines in an Area Depth Profile Measurement that map the
the perpendicular distance between the surface points and the
perpendicular distance between the surface points and the reference
reference surface.
surface.
Projected Plane Measurement – The use of a Measurement Plane
Projected Plane Measurement – The use of a Measurement Plane
in combination with another measurement type to mathematically
in combination with another measurement type to mathematically
project the plane of a surface over the entire image and measure
project the plane of a surface over the entire image and measure on
on that plane.
that plane.
Red Filled Cursors on Depth Profile – Indicates cursor is not on a flat
Red Filled Cursors on Depth Profile – Indicates cursor is not on a flat
surface or not on the same plane. Cursor must be repositioned for
surface or not on the same plane. Cursor must be repositioned for
accurate measurement.
accurate measurement.
Red Mask on Image – Indicates surface data in this area is not
Red Mask on Image – Indicates surface data in this area is not
available for measurement. Moving closer or adjusting viewing
available for measurement. Moving closer or adjusting viewing
orientation may reduce red mask area.
orientation may reduce red mask area.
Reference Line – In a point to line measurement, the first two cursors,
Reference Line – In a point to line measurement, the first two cursors,
placed on unaltered surface points, define a straight reference line
placed on unaltered surface points, define a straight reference line
in 3D space from which the distance to the third cursor point is
in 3D space from which the distance to the third cursor point is
measured.
measured.
VideoProbe 3D Measurement Handbook
VideoProbe 3D Measurement Handbook
VideoProbe 3D Measurement Handbook |
21
109

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido