Recommended installation (PRO750)
1. FILTRATION
2. CONTROL PANEL
3. FLOW SWITCH
4. ELECTROLYSIS CELL
5. PRO750 UNIT(*)
(*) The PRO250, PRO500, PRO750 and PRO1000 units follows the same
hydraulic scheme, connecting in parallel as many cells as power
modules.
It is highly recommended to install a by-pass system, to be able to block
the water flow in each cell for maintenance purposes.
3.2.2- Amperometric probe kit (free chlorine) OPTIONAL.
Amperometric analysis consists of measuring the intensity of
current generated in the reduction or oxidation reaction of an analyte once
a suitable electric potential is applied.
Current intensity is proportional to the amount of hypochlorous acid
present in the solution.
Bear in mind that hypochlorous acid is a weak acid and as such
its distribution depends on the pH of the medium.
Not only does hypochlorous acid respond to the working potential of the
amperometric sensor, but the hypochlorite also reacts. It is therefore
advisable to compensate the response of the sensor depending on
Manual PRO v.2