Using the buttons you can select a line of the menu, indicated by the
arrow (). The OK button is used to confirm the selection.
To access the configuration menu, you need to confirm the operation by
selecting (S) through the arrow, and pressing OK.
4.1.3- Language
From the configuration menu select "Language", press the OK button, and once
the required language has been selected, press the OK button and EXIT.
4.1.4- Control
The equipment allows you to select from 2 different modes of control:
Manual: The equipment produces chlorine continuously, depending on the
% of production selected. If you have a fitted FREE CHLORINE PROBE, it will
ignore its value and chlorination will not stop even though the set value has
been exceeded. When selecting this mode, the equipment will ask if you want
to display the value of the PPM on the main screen.
Select this mode if you do not have a FREE CHLORINE PROBE KIT, by
adjusting production and hours of filtering depending on the nature of your
swimming pool, its volume number of bathers and season of the year.
Automatic
Select this mode only if you do not have an Amperometric probe kit. If
you do not have a probe, the equipment will act at random and end up by
stopping and showing an error.
This mode enables you to automatically adjust the level of chlorine in your
swimming pool. Based on the adjusted set value in the "chlorine" menu, the
equipment will stop when it reaches this value, and start-up again automatically
when there is a need for chlorine.
4.1.5- Cleaning
The equipment includes an automatic cleaning system, based on reversing
polarity in the electrolysis cell. These cleaning cycles are performed regularly.
The time between cleaning (in hours) can be adjusted depending on the water
hardness of your swimming pool.
45 / 53
Manual PRO v.2